Influence of water storage on fatigue strength of self-etch adhesives. Issue 12 (December 2015)
- Record Type:
- Journal Article
- Title:
- Influence of water storage on fatigue strength of self-etch adhesives. Issue 12 (December 2015)
- Main Title:
- Influence of water storage on fatigue strength of self-etch adhesives
- Authors:
- Takamizawa, Toshiki
Barkmeier, Wayne W.
Tsujimoto, Akimasa
Scheidel, Donal D.
Watanabe, Hidehiko
Erickson, Robert L.
Latta, Mark A.
Miyazaki, Masashi - Abstract:
- Abstract: Objectives: The purpose of this study was to determine enamel and dentin bond durability after long-term water storage using self-etch adhesives. Methods: Two single step self-etch adhesives (SU, Scotchbond Universal and GB, G-ӕnial Bond) and a two-step self-etch adhesive (OX, OptiBond XTR) were used. The shear bond strength (SBS) and shear fatigue strength (FS) of the enamel and dentin were obtained with and without phosphoric acid pre-etching prior to application of the adhesives. The specimens were stored in distilled water at 37 °C for 24 h, 6 months, and one year. A staircase method was used to determine the FS using a frequency of 10 Hz for 50, 000 cycles or until failure occurred. Results: The SBS and FS of enamel bonds were significantly higher with pre-etching, when compared to no pre-etching for the same water storage period. The FS of dentin bonds with pre-etching tended to decrease relative to no pre-etching at the same storage period. For the one year storage period, SU and GB with pre-etching showed significantly lower FS values than the groups without pre-etching. Conclusions: The influence of water storage on FS of the self-etch adhesives was dependent on the adhesive material, storage period and phosphoric acid pre-etching of the bonding site. Clinical significance: Phosphoric acid pre-etching of enamel improves the effectiveness of self-etch adhesive systems. Inadvertent contact of phosphoric acid on dentin appears to reduce the ability ofAbstract: Objectives: The purpose of this study was to determine enamel and dentin bond durability after long-term water storage using self-etch adhesives. Methods: Two single step self-etch adhesives (SU, Scotchbond Universal and GB, G-ӕnial Bond) and a two-step self-etch adhesive (OX, OptiBond XTR) were used. The shear bond strength (SBS) and shear fatigue strength (FS) of the enamel and dentin were obtained with and without phosphoric acid pre-etching prior to application of the adhesives. The specimens were stored in distilled water at 37 °C for 24 h, 6 months, and one year. A staircase method was used to determine the FS using a frequency of 10 Hz for 50, 000 cycles or until failure occurred. Results: The SBS and FS of enamel bonds were significantly higher with pre-etching, when compared to no pre-etching for the same water storage period. The FS of dentin bonds with pre-etching tended to decrease relative to no pre-etching at the same storage period. For the one year storage period, SU and GB with pre-etching showed significantly lower FS values than the groups without pre-etching. Conclusions: The influence of water storage on FS of the self-etch adhesives was dependent on the adhesive material, storage period and phosphoric acid pre-etching of the bonding site. Clinical significance: Phosphoric acid pre-etching of enamel improves the effectiveness of self-etch adhesive systems. Inadvertent contact of phosphoric acid on dentin appears to reduce the ability of self-etch adhesives to effectively bond resin composite materials. … (more)
- Is Part Of:
- Journal of dentistry. Volume 43:Issue 12(2015:Dec.)
- Journal:
- Journal of dentistry
- Issue:
- Volume 43:Issue 12(2015:Dec.)
- Issue Display:
- Volume 43, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 43
- Issue:
- 12
- Issue Sort Value:
- 2015-0043-0012-0000
- Page Start:
- 1416
- Page End:
- 1427
- Publication Date:
- 2015-12
- Subjects:
- Fatigue strength -- Self-etch adhesive -- Long-term water storage -- Phosphoric acid pre-etching
Dentistry -- Periodicals
Dentistry -- Periodicals
Dentisterie -- Périodiques
Electronic journals
617.6005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03005712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03005712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jdent.2015.10.018 ↗
- Languages:
- English
- ISSNs:
- 0300-5712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4968.670000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2549.xml