Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study. Issue 12 (December 2015)
- Record Type:
- Journal Article
- Title:
- Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study. Issue 12 (December 2015)
- Main Title:
- Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study
- Authors:
- Möhlhenrich, S.C.
Heussen, N.
Elvers, D.
Steiner, T.
Hölzle, F.
Modabber, A. - Abstract:
- Abstract: The aim of this study was to determine the influence of implant diameter and length on primary stability in artificial bone blocks. In total, 240 implants of various diameters (Ø 3.3, 4.1, and 4.8 mm) and lengths (8 and 12 mm) were inserted in four artificial bone blocks of different densities (D1–D4). The primary stability for each bone block density was measured and compared with the primary stability of a narrow and short implant (Ø 3.3 mm, length 8 mm) in the next higher density block. Analysis was done by three-way ANOVA, and mean differences were determined with the 95% confidence interval. Levels of primary stability achieved by choosing the next higher diameter or length were not comparable to those of the next level of block density. However, equivalent values could be achieved by selecting the largest diameter for short and long implants in the lowest block density D4, as well as for long implants in bone type D2. The diameter of an implant has greater influence on primary stability than length. In particular, in the case of poor bone quality, a variation of implant geometry can lead to significant improvement in primary stability.
- Is Part Of:
- International journal of oral & maxillofacial surgery. Volume 44:Issue 12(2015:Dec.)
- Journal:
- International journal of oral & maxillofacial surgery
- Issue:
- Volume 44:Issue 12(2015:Dec.)
- Issue Display:
- Volume 44, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 44
- Issue:
- 12
- Issue Sort Value:
- 2015-0044-0012-0000
- Page Start:
- 1514
- Page End:
- 1520
- Publication Date:
- 2015-12
- Subjects:
- dental implant -- primary stability -- resonance frequency analysis -- bone density -- bone quality -- implant length -- implant diameter
Mouth -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Dentistry -- Periodicals
Dentistry, Operative
Oral Surgical Procedures
Surgery, Oral
Dentistry
Maxilla -- Surgery
Mouth -- Surgery
Electronic journals
Periodicals
617.52059 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=ijo ↗
http://www.sciencedirect.com/science/journal/09015027 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09015027 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09015027 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijom.2015.08.985 ↗
- Languages:
- English
- ISSNs:
- 0901-5027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.429800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 710.xml