Simultaneous achievement of accurate CT number and image quality improvement for myocardial perfusion CT at 320-MDCT volume scanning. Issue 7 (November 2015)
- Record Type:
- Journal Article
- Title:
- Simultaneous achievement of accurate CT number and image quality improvement for myocardial perfusion CT at 320-MDCT volume scanning. Issue 7 (November 2015)
- Main Title:
- Simultaneous achievement of accurate CT number and image quality improvement for myocardial perfusion CT at 320-MDCT volume scanning
- Authors:
- Funama, Yoshinori
Taguchi, Katsuyuki
Utsunomiya, Daisuke
Oda, Seitaro
Shimonobo, Toshiaki
Yuki, Hideaki
Kidoh, Masafumi
Yamashita, Yasuyuki - Abstract:
- Abstract: Purpose: To investigate differences in image-to-image variations between full- and half-scan reconstruction on myocardial CT perfusion (CTP) study. Methods: Using a cardiac phantom we performed ECG-gated myocardial CTP on a second-generation 320-multidetector CT volume scanner. The heart rate was set at 60 bpm; once per second for a total of 24 s were performed. CT images were acquired at 80- and 120 kVp and subjected to full- and half-scan reconstruction. On images acquired at the same slice level we then measured image-to-image variations, coefficients of variance (CV), and image noise. Results: The image-to-image variations with full- and half-scan reconstruction were 1.3 HU vs. 27.2 HU at 80 kVp (p < 0.001) and 0.70 HU vs. 9.3 HU at 120 kVp (p < 0.001) even though the mean HU value was almost the same for both reconstruction methods. The CV of 80- and 120-kVp images of the left ventricular cavity decreased by 0.16% and 0.17%, respectively, with full-scan reconstruction; with half-scan reconstruction it decreased by 3.34% and 2.30%, respectively. Compared with half-scan reconstruction, the image noise was reduced by 27.2% at 80 kVp and by 28.0% at 120 kVp with full-scan reconstruction. Conclusion: Myocardial CTP with full-scan reconstruction substantially decreased image-to-image variations and provided accurate CT attenuation. Highlights: Image-to-image variations were lower with full-than half-scan reconstruction. Image noise and X-ray dose were lower withAbstract: Purpose: To investigate differences in image-to-image variations between full- and half-scan reconstruction on myocardial CT perfusion (CTP) study. Methods: Using a cardiac phantom we performed ECG-gated myocardial CTP on a second-generation 320-multidetector CT volume scanner. The heart rate was set at 60 bpm; once per second for a total of 24 s were performed. CT images were acquired at 80- and 120 kVp and subjected to full- and half-scan reconstruction. On images acquired at the same slice level we then measured image-to-image variations, coefficients of variance (CV), and image noise. Results: The image-to-image variations with full- and half-scan reconstruction were 1.3 HU vs. 27.2 HU at 80 kVp (p < 0.001) and 0.70 HU vs. 9.3 HU at 120 kVp (p < 0.001) even though the mean HU value was almost the same for both reconstruction methods. The CV of 80- and 120-kVp images of the left ventricular cavity decreased by 0.16% and 0.17%, respectively, with full-scan reconstruction; with half-scan reconstruction it decreased by 3.34% and 2.30%, respectively. Compared with half-scan reconstruction, the image noise was reduced by 27.2% at 80 kVp and by 28.0% at 120 kVp with full-scan reconstruction. Conclusion: Myocardial CTP with full-scan reconstruction substantially decreased image-to-image variations and provided accurate CT attenuation. Highlights: Image-to-image variations were lower with full-than half-scan reconstruction. Image noise and X-ray dose were lower with full-than half-scan reconstruction. Myocardial CTP imaging yields better contrast resolution at a lower tube voltage. … (more)
- Is Part Of:
- Physica medica. Volume 31:Issue 7(2015)
- Journal:
- Physica medica
- Issue:
- Volume 31:Issue 7(2015)
- Issue Display:
- Volume 31, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 7
- Issue Sort Value:
- 2015-0031-0007-0000
- Page Start:
- 702
- Page End:
- 707
- Publication Date:
- 2015-11
- Subjects:
- Full-scan reconstruction -- Myocardial CT perfusion -- Image-to-image variation -- Half-scan reconstruction -- 320-Detector volume scanner
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2015.05.018 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2165.xml