High resolution MR eye protocol optimization: Comparison between 3D-CISS, 3D-PSIF and 3D-VIBE sequences. Issue 7 (November 2015)
- Record Type:
- Journal Article
- Title:
- High resolution MR eye protocol optimization: Comparison between 3D-CISS, 3D-PSIF and 3D-VIBE sequences. Issue 7 (November 2015)
- Main Title:
- High resolution MR eye protocol optimization: Comparison between 3D-CISS, 3D-PSIF and 3D-VIBE sequences
- Authors:
- Tsiapa, Irene
Tsilimbaris, Miltiadis K.
Papadaki, Efrosini
Bouziotis, Penelope
Pallikaris, Ioannis G.
Karantanas, Apostolos H.
Maris, Thomas G. - Abstract:
- Abstract: Purpose: The purpose of this study was to compare selected MRI pulse sequences and to evaluate their utility for depicting specific anatomic regions in the eye. Methods: A High-Resolution (HR) 0.08 × 0.08 × 0.60 mm 3 MRI protocol was developed on a 1.5-T clinical system and applied in the left eye of an albino rabbit, utilizing a small field of view surface coil. The comprehensive MRI protocol consisted of two 3D (T2/T1)w sequences (3D-PSIF and 3D-CISS), and one 3D T1w sequence (3D-VIBE). The T1w 3D-VIBE sequence was acquired, before and after intravenous injection of 0.2 mmol/kgr gadolinium-DTPA. Signal-to-Noise Ratios (SNR) and Contrast-to-Noise Ratios (CNR) amongst specific eye anatomical areas were calculated for each sequence. The presence of artifacts was rated subjectively utilizing a 5 point scale. Results: 3D-PSIF and 3D-CISS provide better delineation and visualization of the eye as compared with 3D-VIBE sequences. 3D-CISS images present the highest SNR and revealed better discrimination of the ocular surrounding tissues; its basic drawback though is related to ghost artifacts appearing in the anterior chamber and resulting in the lowest image quality. In post-contrast imaging, the T1w 3D-VIBE sequence provided the best overall image quality. Moreover, 3D (T2/T1)w sequences can provide good anatomic depiction of the eye segments. Agreement between the two independent readers was good. Conclusions: Optimization of a comprehensive MR eye imaging protocol isAbstract: Purpose: The purpose of this study was to compare selected MRI pulse sequences and to evaluate their utility for depicting specific anatomic regions in the eye. Methods: A High-Resolution (HR) 0.08 × 0.08 × 0.60 mm 3 MRI protocol was developed on a 1.5-T clinical system and applied in the left eye of an albino rabbit, utilizing a small field of view surface coil. The comprehensive MRI protocol consisted of two 3D (T2/T1)w sequences (3D-PSIF and 3D-CISS), and one 3D T1w sequence (3D-VIBE). The T1w 3D-VIBE sequence was acquired, before and after intravenous injection of 0.2 mmol/kgr gadolinium-DTPA. Signal-to-Noise Ratios (SNR) and Contrast-to-Noise Ratios (CNR) amongst specific eye anatomical areas were calculated for each sequence. The presence of artifacts was rated subjectively utilizing a 5 point scale. Results: 3D-PSIF and 3D-CISS provide better delineation and visualization of the eye as compared with 3D-VIBE sequences. 3D-CISS images present the highest SNR and revealed better discrimination of the ocular surrounding tissues; its basic drawback though is related to ghost artifacts appearing in the anterior chamber and resulting in the lowest image quality. In post-contrast imaging, the T1w 3D-VIBE sequence provided the best overall image quality. Moreover, 3D (T2/T1)w sequences can provide good anatomic depiction of the eye segments. Agreement between the two independent readers was good. Conclusions: Optimization of a comprehensive MR eye imaging protocol is achieved. A higher SNR, a better spatial resolution and a reduction of the total scan time were obtained, thus making clinical MRI systems more reliable in eye imaging. Highlights: High-resolution Magnetic Resonance Imaging (HR-MRI) of the eye. Optimization of MRI protocol at 1.5T clinical system for ocular imaging. High spatial resolution 0.08 × 0.08 × 0.60 mm 3 within a rapid scanning time (3.5 min). 3D (T2/T1)w sequences (3D-PSIF and 3D-CISS). 3D T1w sequence (3D-VIBE) pre and post-Gd injection. … (more)
- Is Part Of:
- Physica medica. Volume 31:Issue 7(2015)
- Journal:
- Physica medica
- Issue:
- Volume 31:Issue 7(2015)
- Issue Display:
- Volume 31, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 7
- Issue Sort Value:
- 2015-0031-0007-0000
- Page Start:
- 774
- Page End:
- 780
- Publication Date:
- 2015-11
- Subjects:
- MR eye -- Ophthalmology -- Ocular tissues -- High-resolution MRI
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2015.03.009 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2165.xml