Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom. Issue 7 (November 2015)
- Record Type:
- Journal Article
- Title:
- Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom. Issue 7 (November 2015)
- Main Title:
- Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom
- Authors:
- Tzamicha, E.
Yakoumakis, E.
Tsalafoutas, I.A.
Dimitriadis, A.
Georgiou, E.
Tsapaki, V.
Chalazonitis, A. - Abstract:
- Abstract: Purpose: To estimate the mean glandular dose of contrast enhanced digital mammography, using the EGSnrc Monte Carlo code and female adult voxel phantom. Methods: Automatic exposure control of full field digital mammography system was used for the selection of the X-ray spectrum and the exposure settings for dual energy imaging. Measurements of the air-kerma and of the half value layers were performed and a Monte Carlo simulation of the digital mammography system was used to compute the mean glandular dose, for breast phantoms of various thicknesses, glandularities and for different X-ray spectra (low and high energy). Results: For breast phantoms of 2.0–8.0 cm thick and 0.1–100% glandular fraction, CC view acquisition, from AEC settings, can result in a mean glandular dose of 0.450 ± 0.022 mGy −2.575 ± 0.033 mGy for low energy images and 0.061 ± 0.021 mGy – 0.232 ± 0.033 mGy for high energy images. In MLO view acquisition mean glandular dose values ranged between 0.488 ± 0.007 mGy – 2.080 ± 0.021 mGy for low energy images and 0.065 ± 0.012 mGy – 0.215 ± 0.010 mGy for high energy images. Conclusion: The low kV part of contrast enhanced digital mammography is the main contributor to total mean glandular breast dose. The results of this study can be used to provide an estimated mean glandular dose for individual cases. Highlights: Estimation the Glandular Dose of Contrast Enhanced Digital Mammography (CEDM). The low kV part of CEDM is the main contributor to totalAbstract: Purpose: To estimate the mean glandular dose of contrast enhanced digital mammography, using the EGSnrc Monte Carlo code and female adult voxel phantom. Methods: Automatic exposure control of full field digital mammography system was used for the selection of the X-ray spectrum and the exposure settings for dual energy imaging. Measurements of the air-kerma and of the half value layers were performed and a Monte Carlo simulation of the digital mammography system was used to compute the mean glandular dose, for breast phantoms of various thicknesses, glandularities and for different X-ray spectra (low and high energy). Results: For breast phantoms of 2.0–8.0 cm thick and 0.1–100% glandular fraction, CC view acquisition, from AEC settings, can result in a mean glandular dose of 0.450 ± 0.022 mGy −2.575 ± 0.033 mGy for low energy images and 0.061 ± 0.021 mGy – 0.232 ± 0.033 mGy for high energy images. In MLO view acquisition mean glandular dose values ranged between 0.488 ± 0.007 mGy – 2.080 ± 0.021 mGy for low energy images and 0.065 ± 0.012 mGy – 0.215 ± 0.010 mGy for high energy images. Conclusion: The low kV part of contrast enhanced digital mammography is the main contributor to total mean glandular breast dose. The results of this study can be used to provide an estimated mean glandular dose for individual cases. Highlights: Estimation the Glandular Dose of Contrast Enhanced Digital Mammography (CEDM). The low kV part of CEDM is the main contributor to total Glandular Breast Dose. The high kV part does not exceed 0.3 mGy for any breast thicknesses. The results of this study can be used to provide an estimated Glandular Dose for individual cases. … (more)
- Is Part Of:
- Physica medica. Volume 31:Issue 7(2015)
- Journal:
- Physica medica
- Issue:
- Volume 31:Issue 7(2015)
- Issue Display:
- Volume 31, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 7
- Issue Sort Value:
- 2015-0031-0007-0000
- Page Start:
- 785
- Page End:
- 791
- Publication Date:
- 2015-11
- Subjects:
- CEDM -- Dosimetry -- Monte Carlo -- Breast -- Mammography -- Voxel phantom
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2015.03.013 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2165.xml