Application of superporous magnetic cationic cryogels for persistent chromate (toxic chromate and dichromate) uptake from aqueous environments. Issue 20 (8th February 2016)
- Record Type:
- Journal Article
- Title:
- Application of superporous magnetic cationic cryogels for persistent chromate (toxic chromate and dichromate) uptake from aqueous environments. Issue 20 (8th February 2016)
- Main Title:
- Application of superporous magnetic cationic cryogels for persistent chromate (toxic chromate and dichromate) uptake from aqueous environments
- Authors:
- Sahiner, Nurettin
Demirci, Sahin
Sahiner, Mehtap
Yilmaz, Selehattin - Abstract:
- ABSTRACT: Poly((3‐Acrylamidopropyl)trimethylammonium chloride) (p(APTMACl)) cryogels were prepared with cryopolymerization technique and employed for the removal of toxic chromate and dichromate anions from aqueous media. The maximum adsorption capacities of 94 mg/g and 135 mg/g for chromate and dichromate anions, respectively, were determined with the application of the Langmuir isotherm. These values are very close to the experimental values of about 77 and 128 mg/g from 100 mL, 100 ppm chromate, and dichromate solutions using 0.03 g cryogel. The removal efficiency of chromate and dichromate anions were increased with the increase in the amount of cryogel and the removal percentage of chromate and dichromate toxic anions were estimated as 99.21 and 93.61%, respectively, for 0.15 g of p(APTMACl) cryogels used in 100 mL, 100 ppm chromate, and dichromate solutions. Furthermore, magnetic p(APTMACl) cryogels were also prepared and used in the removal of chromate and dichromate, and the maximum adsorption capacities were 30 mg/g and 40 mg/g, respectively. Additionally, the adsorption of these anions were investigated from different media such as drinking water, tap water, seawater, and creek water; and the maximum adsorption amounts in drinking water were 65.5 ± 15, and 125.5 ± 11 mg/g for chromate and dichromate anions, respectively. The reusability of p(APTMACl) cryogels for the removal of chromate and dichromate anions was also investigated, and it was found that theABSTRACT: Poly((3‐Acrylamidopropyl)trimethylammonium chloride) (p(APTMACl)) cryogels were prepared with cryopolymerization technique and employed for the removal of toxic chromate and dichromate anions from aqueous media. The maximum adsorption capacities of 94 mg/g and 135 mg/g for chromate and dichromate anions, respectively, were determined with the application of the Langmuir isotherm. These values are very close to the experimental values of about 77 and 128 mg/g from 100 mL, 100 ppm chromate, and dichromate solutions using 0.03 g cryogel. The removal efficiency of chromate and dichromate anions were increased with the increase in the amount of cryogel and the removal percentage of chromate and dichromate toxic anions were estimated as 99.21 and 93.61%, respectively, for 0.15 g of p(APTMACl) cryogels used in 100 mL, 100 ppm chromate, and dichromate solutions. Furthermore, magnetic p(APTMACl) cryogels were also prepared and used in the removal of chromate and dichromate, and the maximum adsorption capacities were 30 mg/g and 40 mg/g, respectively. Additionally, the adsorption of these anions were investigated from different media such as drinking water, tap water, seawater, and creek water; and the maximum adsorption amounts in drinking water were 65.5 ± 15, and 125.5 ± 11 mg/g for chromate and dichromate anions, respectively. The reusability of p(APTMACl) cryogels for the removal of chromate and dichromate anions was also investigated, and it was found that the adsorption capacity for chromate anions decreased to 71.23 ± 4.3 from 97.37 ± 4.5 mg/g, whereas the adsorption capacity of dichromate anions only decreased to 123.69 ± 3.5 mg/g from 129.9 ± 7 mg/g at the end of five adsorption‐desorption cycles. © 2016 Wiley Periodicals, Inc. J. Appl. Polym. Sci.2016, 133, 43438. Abstract : … (more)
- Is Part Of:
- Journal of applied polymer science. Volume 133:Issue 20(2016)
- Journal:
- Journal of applied polymer science
- Issue:
- Volume 133:Issue 20(2016)
- Issue Display:
- Volume 133, Issue 20 (2016)
- Year:
- 2016
- Volume:
- 133
- Issue:
- 20
- Issue Sort Value:
- 2016-0133-0020-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-02-08
- Subjects:
- adsorption -- crosslinking -- gels -- hydrophilic polymers -- surfaces and interfaces
Polymers -- Periodicals
Polymerization -- Periodicals
668.9 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-4628 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/app.43438 ↗
- Languages:
- English
- ISSNs:
- 0021-8995
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4946.600000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1532.xml