Cryoballoon Ablation for Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation: One-Year Outcome Using Second Generation Cryoballoon. (October 2015)
- Record Type:
- Journal Article
- Title:
- Cryoballoon Ablation for Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation: One-Year Outcome Using Second Generation Cryoballoon. (October 2015)
- Main Title:
- Cryoballoon Ablation for Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation
- Authors:
- Koektuerk, Buelent
Yorgun, Hikmet
Hengeoez, Oezlem
Turan, Cem H.
Dahmen, Alina
Yang, Alexander
Bansmann, Paul M.
Gorr, Eduard
Hoppe, Christian
Turan, Ramazan G.
Horlitz, Marc - Abstract:
- Abstract : Background—: Data regarding the freedom from atrial fibrillation (AF) in the follow-up of persistent AF patients is limited. The second-generation cryoballoon has better cooling properties compared with first-generation cryoballon. In this study, we aimed to assess the medium-term efficacy of second-generation cryoballoon in patients with persistent AF. Methods and Results—: A total of 100 patients (63±10 years, 80% male) with symptomatic persistent AF, despite ≥1 antiarrhythmic drug(s), who were scheduled for pulmonary vein isolation using second-generation cryoballoon were enrolled in this study. Follow-up was based on outpatient clinic visits, including Holter ECGs. Recurrence was defined as a symptomatic or documented arrhythmia episode of >30 seconds excluding a 3-month blanking period. As a result, 393 pulmonary veins (7 patients with common ostium) were successfully isolated. Mean procedural and fluoroscopy times were 96.2±21.3 and 19.7±6.7 minutes, respectively. Phrenic nerve palsy occurred in 3% (3/100) of the patients. At a mean follow-up duration of 10.6±6.3 months, 67% of the patients were in sinus rhythm. Stepwise multivariable Cox proportional hazard regression analysis showed that early AF recurrence (hazard ratio 3.83, 95% confidence interval 1.91–7.68, P <0.001) was the only independent predictor for late AF recurrence apart from other clinical and echocardiographic variables. Conclusions—: Our findings indicated that second-generation cryoballoonAbstract : Background—: Data regarding the freedom from atrial fibrillation (AF) in the follow-up of persistent AF patients is limited. The second-generation cryoballoon has better cooling properties compared with first-generation cryoballon. In this study, we aimed to assess the medium-term efficacy of second-generation cryoballoon in patients with persistent AF. Methods and Results—: A total of 100 patients (63±10 years, 80% male) with symptomatic persistent AF, despite ≥1 antiarrhythmic drug(s), who were scheduled for pulmonary vein isolation using second-generation cryoballoon were enrolled in this study. Follow-up was based on outpatient clinic visits, including Holter ECGs. Recurrence was defined as a symptomatic or documented arrhythmia episode of >30 seconds excluding a 3-month blanking period. As a result, 393 pulmonary veins (7 patients with common ostium) were successfully isolated. Mean procedural and fluoroscopy times were 96.2±21.3 and 19.7±6.7 minutes, respectively. Phrenic nerve palsy occurred in 3% (3/100) of the patients. At a mean follow-up duration of 10.6±6.3 months, 67% of the patients were in sinus rhythm. Stepwise multivariable Cox proportional hazard regression analysis showed that early AF recurrence (hazard ratio 3.83, 95% confidence interval 1.91–7.68, P <0.001) was the only independent predictor for late AF recurrence apart from other clinical and echocardiographic variables. Conclusions—: Our findings indicated that second-generation cryoballoon use is associated with favorable outcomes in patients with persistent AF. Recurrence at blanking period was the only predictor of long-term AF recurrence. … (more)
- Is Part Of:
- Circulation. Volume 8:Number 5(2015)
- Journal:
- Circulation
- Issue:
- Volume 8:Number 5(2015)
- Issue Display:
- Volume 8, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 8
- Issue:
- 5
- Issue Sort Value:
- 2015-0008-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10
- Subjects:
- cryoballoon ablation -- persistent atrial fibrillation -- pulmonary vein isolation
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.115.002776 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1629.xml