Left Atrial Appendage Occlusion Device and Novel Oral Anticoagulants Versus Warfarin for Stroke Prevention in Nonvalvular Atrial Fibrillation: Systematic Review and Meta-Analysis of Randomized Controlled Trials. (October 2015)
- Record Type:
- Journal Article
- Title:
- Left Atrial Appendage Occlusion Device and Novel Oral Anticoagulants Versus Warfarin for Stroke Prevention in Nonvalvular Atrial Fibrillation: Systematic Review and Meta-Analysis of Randomized Controlled Trials. (October 2015)
- Main Title:
- Left Atrial Appendage Occlusion Device and Novel Oral Anticoagulants Versus Warfarin for Stroke Prevention in Nonvalvular Atrial Fibrillation
- Authors:
- Briceno, David F.
Villablanca, Pedro
Cyrille, Nicole
Massera, Daniele
Bader, Eric
Manheimer, Eric
Aagaard, Philip
Ferrick, Kevin
Gross, Jay
Kim, Soo Gyum
Krumerman, Andrew
Palma, Eugen
Guttenplan, Nils
Romero, Jorge
Fisher, John
Garcia, Mario
Natale, Andrea
Di Biase, Luigi - Abstract:
- Abstract : Background—: Nonvalvular atrial fibrillation is the most common arrhythmia. Patients with nonvalvular atrial fibrillation are at increased risk of stroke; therefore, we evaluated the efficacy and safety of different approaches to prevent this major complication. Methods and Results—: We conducted electronic database searches of phase III randomized controlled trials. The groups were novel oral anticoagulants, Watchman left atrial appendage occlusion device (DEVICE), and warfarin. Efficacy outcomes were stroke or systemic embolism, and all-cause mortality. Safety outcome was major bleeding and procedure-related complications. A subgroup analysis of the elderly population was done. We used random-effects model to compare pooled outcomes and tested for heterogeneity. Odds ratios (ORs) and 95% confidence intervals (CIs) were computed for each outcome. Seven randomized controlled trials (n=73 978) were included. There was a significant difference favoring novel oral anticoagulants for systemic embolism (OR, 0.84; 95% CI, 0.72–0.97; P =0.01), all-cause mortality (OR, 0.89; 95% CI, 0.84–0.94; P <0.001), and safety outcomes (OR, 0.79; 95% CI, 0.65–0.97; P =0.026) compared with warfarin. No difference was seen between DEVICE and warfarin for efficacy end points; however, DEVICE had more complications (OR, 1.85; 95% CI, 1.14–3.01; P =0.012). In the elderly (6 randomized controlled trials, n=30 699), systemic embolism was favored with novel oral anticoagulants over warfarinAbstract : Background—: Nonvalvular atrial fibrillation is the most common arrhythmia. Patients with nonvalvular atrial fibrillation are at increased risk of stroke; therefore, we evaluated the efficacy and safety of different approaches to prevent this major complication. Methods and Results—: We conducted electronic database searches of phase III randomized controlled trials. The groups were novel oral anticoagulants, Watchman left atrial appendage occlusion device (DEVICE), and warfarin. Efficacy outcomes were stroke or systemic embolism, and all-cause mortality. Safety outcome was major bleeding and procedure-related complications. A subgroup analysis of the elderly population was done. We used random-effects model to compare pooled outcomes and tested for heterogeneity. Odds ratios (ORs) and 95% confidence intervals (CIs) were computed for each outcome. Seven randomized controlled trials (n=73 978) were included. There was a significant difference favoring novel oral anticoagulants for systemic embolism (OR, 0.84; 95% CI, 0.72–0.97; P =0.01), all-cause mortality (OR, 0.89; 95% CI, 0.84–0.94; P <0.001), and safety outcomes (OR, 0.79; 95% CI, 0.65–0.97; P =0.026) compared with warfarin. No difference was seen between DEVICE and warfarin for efficacy end points; however, DEVICE had more complications (OR, 1.85; 95% CI, 1.14–3.01; P =0.012). In the elderly (6 randomized controlled trials, n=30 699), systemic embolism was favored with novel oral anticoagulants over warfarin (OR, 0.77; 95% CI, 0.68–0.87; P ⩽0.001). No evidence of significant publication bias was found. Conclusions—: Novel oral anticoagulants is superior to warfarin for stroke prevention in nonvalvular atrial fibrillation. This benefit was also observed in the elderly population. DEVICE is a reasonable noninferior alternative to warfarin for stroke prevention, but cautious use is essential given safety concerns. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 8:Number 5(2015)
- Journal:
- Circulation
- Issue:
- Volume 8:Number 5(2015)
- Issue Display:
- Volume 8, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 8
- Issue:
- 5
- Issue Sort Value:
- 2015-0008-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10
- Subjects:
- anticoagulants -- atrial appendage -- atrial fibrillation -- stroke -- warfarin
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.115.002993 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1629.xml