A prospective pilot study in assessing the accuracy of ultrasound estimated fetal weight prior to delivery. (24th August 2015)
- Record Type:
- Journal Article
- Title:
- A prospective pilot study in assessing the accuracy of ultrasound estimated fetal weight prior to delivery. (24th August 2015)
- Main Title:
- A prospective pilot study in assessing the accuracy of ultrasound estimated fetal weight prior to delivery
- Authors:
- Sekar, Renuka
Khatun, Mohsina
Barrett, Helen L.
Duncombe, Gregory - Abstract:
- Abstract : Background: Perinatal mortality and morbidity related to growth restriction and macrosomia are predicted by birthweight. Estimated fetal weight is a surrogate measure for neonatal weight, and accurate measurement of this is central to providing counselling and managing preterm birth. Aims: To assess the accuracy of estimated fetal weight (EFW) measured by two sonographers within 1 week of delivery using Hadlock formula. Materials and Methods: Two sonographers independently scanned 150 women with singleton pregnancies, who were booked for elective delivery. The sonographers measured four biometric measurements in estimating fetal weight. The accuracy of EFW compared to the birthweight was examined. We also assessed the sensitivity and specificity for diagnosis of small‐for‐gestational age (SGA) and large–for‐gestational age (LGA) according to the EFW. Results: Estimated fetal weight was similar to actual birthweight, with a mean percentage difference (SD) of 1.4(7.0) ( P = 0.44). The reliability coefficient of EFW compared to actual birthweight was 0.97 (95% CI (0.96, 0.98)). There was no significant difference between the sonographers for EFWs and among the sonographers from the ultrasound scan to delivery interval. The sensitivity and specificity for detection of SGA and LGA were 93.3% and 99.3%, 60% and 95.6%, respectively. Conclusions: There is high reproducibility with minimum discrepancy from actual birthweight among sonographers 1 week prior to deliveryAbstract : Background: Perinatal mortality and morbidity related to growth restriction and macrosomia are predicted by birthweight. Estimated fetal weight is a surrogate measure for neonatal weight, and accurate measurement of this is central to providing counselling and managing preterm birth. Aims: To assess the accuracy of estimated fetal weight (EFW) measured by two sonographers within 1 week of delivery using Hadlock formula. Materials and Methods: Two sonographers independently scanned 150 women with singleton pregnancies, who were booked for elective delivery. The sonographers measured four biometric measurements in estimating fetal weight. The accuracy of EFW compared to the birthweight was examined. We also assessed the sensitivity and specificity for diagnosis of small‐for‐gestational age (SGA) and large–for‐gestational age (LGA) according to the EFW. Results: Estimated fetal weight was similar to actual birthweight, with a mean percentage difference (SD) of 1.4(7.0) ( P = 0.44). The reliability coefficient of EFW compared to actual birthweight was 0.97 (95% CI (0.96, 0.98)). There was no significant difference between the sonographers for EFWs and among the sonographers from the ultrasound scan to delivery interval. The sensitivity and specificity for detection of SGA and LGA were 93.3% and 99.3%, 60% and 95.6%, respectively. Conclusions: There is high reproducibility with minimum discrepancy from actual birthweight among sonographers 1 week prior to delivery using Hadlock formula with better prediction of SGA neonates. … (more)
- Is Part Of:
- Australian and New Zealand journal of obstetrics and gynaecology. Volume 56:Number 1(2016:Feb.)
- Journal:
- Australian and New Zealand journal of obstetrics and gynaecology
- Issue:
- Volume 56:Number 1(2016:Feb.)
- Issue Display:
- Volume 56, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 56
- Issue:
- 1
- Issue Sort Value:
- 2016-0056-0001-0000
- Page Start:
- 49
- Page End:
- 53
- Publication Date:
- 2015-08-24
- Subjects:
- accuracy prior to delivery -- estimated fetal weight -- interobserver reliability
Obstetrics -- Periodicals
Gynecology -- Periodicals
618.05 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1479-828X ↗
http://www.blackwell-synergy.com/loi/ajo ↗
http://www3.interscience.wiley.com/journal/118501330/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ajo.12391 ↗
- Languages:
- English
- ISSNs:
- 0004-8666
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1796.890000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2472.xml