Inter‐ and intra‐fraction motion in stereotactic body radiotherapy for spinal and paraspinal tumours using cone‐beam CT and positional correction in six degrees of freedom. Issue 1 (7th September 2015)
- Record Type:
- Journal Article
- Title:
- Inter‐ and intra‐fraction motion in stereotactic body radiotherapy for spinal and paraspinal tumours using cone‐beam CT and positional correction in six degrees of freedom. Issue 1 (7th September 2015)
- Main Title:
- Inter‐ and intra‐fraction motion in stereotactic body radiotherapy for spinal and paraspinal tumours using cone‐beam CT and positional correction in six degrees of freedom
- Authors:
- Finnigan, Renee
Lamprecht, Brock
Barry, Tamara
Jones, Kimberley
Boyd, Joshua
Pullar, Andrew
Burmeister, Bryan
Foote, Matthew - Abstract:
- Abstract: Introduction: Stereotactic body radiotherapy (SBRT) for spinal tumours delivers high doses per fraction to targets in close proximity to neural tissue. With steep dose gradients, small changes in position can confer significant dosimetric impact on adjacent structures. We analysed positioning error in consecutively treated patients on a strict image‐guidance protocol with online correction in 6 degrees of freedom (6‐DOF). Methods: Set‐up error, residual error post‐correction and intra‐fraction motion for 30 courses of spinal SBRT in 27 patients were assessed using cone‐beam CT. Positional error was corrected in x, y and z translational planes and rotational axes using a robotic couch, applying 2 mm and 2° action levels. Linear mixed‐effects model assessed whether positional error was influenced by factors such as vertebral level, immobilisation device and treatment duration. Results: Sixty‐two fractions were delivered with 225 image registrations. Median treatment duration was significantly longer for patients treated with static‐field intensity‐modulated radiotherapy compared with volumetric‐modulated arc treatment – 40 min versus 28 min, respectively ( P = 0.01). Across all fractions, the median residual positional error after initial correction was greatest in the x translational plane (0.5 mm; 95% confidence interval (CI) 0.3–0.6) and y rotational axis (0.25°; 95% CI 0.1–0.3). Median intra‐fraction error was also greatest in the x ‐plane (0.7 mm; 95% CIAbstract: Introduction: Stereotactic body radiotherapy (SBRT) for spinal tumours delivers high doses per fraction to targets in close proximity to neural tissue. With steep dose gradients, small changes in position can confer significant dosimetric impact on adjacent structures. We analysed positioning error in consecutively treated patients on a strict image‐guidance protocol with online correction in 6 degrees of freedom (6‐DOF). Methods: Set‐up error, residual error post‐correction and intra‐fraction motion for 30 courses of spinal SBRT in 27 patients were assessed using cone‐beam CT. Positional error was corrected in x, y and z translational planes and rotational axes using a robotic couch, applying 2 mm and 2° action levels. Linear mixed‐effects model assessed whether positional error was influenced by factors such as vertebral level, immobilisation device and treatment duration. Results: Sixty‐two fractions were delivered with 225 image registrations. Median treatment duration was significantly longer for patients treated with static‐field intensity‐modulated radiotherapy compared with volumetric‐modulated arc treatment – 40 min versus 28 min, respectively ( P = 0.01). Across all fractions, the median residual positional error after initial correction was greatest in the x translational plane (0.5 mm; 95% confidence interval (CI) 0.3–0.6) and y rotational axis (0.25°; 95% CI 0.1–0.3). Median intra‐fraction error was also greatest in the x ‐plane (0.7 mm; 95% CI 0.5–1.0) and y ‐axis (0.4°; 95% CI 0.2–0.5). Conclusion: With strict immobilisation, image‐guidance and 6‐DOF correction, our current practice of applying 3‐mm planning margins for target volumes and critical structures appears safe. Lower image‐guidance action thresholds plus verification with end‐to‐end testing would be recommended before further reducing margins. … (more)
- Is Part Of:
- Journal of medical imaging and radiation oncology. Volume 60:Issue 1(2016:Feb.)
- Journal:
- Journal of medical imaging and radiation oncology
- Issue:
- Volume 60:Issue 1(2016:Feb.)
- Issue Display:
- Volume 60, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2016-0060-0001-0000
- Page Start:
- 112
- Page End:
- 118
- Publication Date:
- 2015-09-07
- Subjects:
- cone‐beam computed tomography -- image‐guided radiotherapy -- radiosurgery -- spine -- stereotactic
Radiology, Medical -- Periodicals
Radiology, Medical -- Australasia -- Periodicals
616.0757 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1754-9485 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1754-9485.12353 ↗
- Languages:
- English
- ISSNs:
- 1754-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.072080
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: