Testing the Assessment of New Radiation Oncology Technology and Treatments framework using the evaluation of post‐prostatectomy radiotherapy techniques. Issue 1 (5th October 2015)
- Record Type:
- Journal Article
- Title:
- Testing the Assessment of New Radiation Oncology Technology and Treatments framework using the evaluation of post‐prostatectomy radiotherapy techniques. Issue 1 (5th October 2015)
- Main Title:
- Testing the Assessment of New Radiation Oncology Technology and Treatments framework using the evaluation of post‐prostatectomy radiotherapy techniques
- Authors:
- Duchesne, Gillian M
Haworth, Annette
Bone, Eric
Carter, Hannah
Ebert, Martin A
Gagliardi, Frank
Gibbs, Adrian
Hornby, Colin
Martin, Andrew
Sidhom, Mark
Wood, Maree
Jackson, Michael - Abstract:
- Abstract: Introduction: We tested the ability of the Assessment of New Radiation Oncology Technology and Treatments framework to determine the clinical efficacy and safety of intensity‐modulated radiation therapy (IMRT) compared with 3‐dimensional radiation therapy (3DCRT) for post‐prostatectomy radiation therapy (PPRT) to support its timely health economic evaluation. Methods: Treatment plans produced using FROGG2 guidelines provided dosimetry parameters for both techniques at 64 Gy and 70 Gy and were also used to model early and late outcome probabilities. Clinical parameters were derived from early toxicity and quality of life patient data, systematic literature review and expert opinion. Dosimetry parameters were correlated with the measures of clinical efficacy and safety. Results: Data from two patient cohorts (29 and 27 respectively) were collected within the project timeframe, providing evidence for acute toxicity and quality of life, and dosimetric comparisons. Relative rates of tumour control probability (TCP) and normal tissue control probability (NTCP) modelling were readily derived from the planning exercise and demonstrated advantages in uncomplicated TCP for IMRT over 3DCRT, predominantly due to normal tissue sparing. The safety of IMRT delivery was demonstrated with TCP uncompromised by IMRT protocol violations, which achieved rectal sparing only by reducing minimum target dose and coverage. Conclusion: Sources of desk‐top and patient‐based evidence wereAbstract: Introduction: We tested the ability of the Assessment of New Radiation Oncology Technology and Treatments framework to determine the clinical efficacy and safety of intensity‐modulated radiation therapy (IMRT) compared with 3‐dimensional radiation therapy (3DCRT) for post‐prostatectomy radiation therapy (PPRT) to support its timely health economic evaluation. Methods: Treatment plans produced using FROGG2 guidelines provided dosimetry parameters for both techniques at 64 Gy and 70 Gy and were also used to model early and late outcome probabilities. Clinical parameters were derived from early toxicity and quality of life patient data, systematic literature review and expert opinion. Dosimetry parameters were correlated with the measures of clinical efficacy and safety. Results: Data from two patient cohorts (29 and 27 respectively) were collected within the project timeframe, providing evidence for acute toxicity and quality of life, and dosimetric comparisons. Relative rates of tumour control probability (TCP) and normal tissue control probability (NTCP) modelling were readily derived from the planning exercise and demonstrated advantages in uncomplicated TCP for IMRT over 3DCRT, predominantly due to normal tissue sparing. The safety of IMRT delivery was demonstrated with TCP uncompromised by IMRT protocol violations, which achieved rectal sparing only by reducing minimum target dose and coverage. Conclusion: Sources of desk‐top and patient‐based evidence were successfully used to demonstrate potential improved clinical efficacy and safety of applying dose escalation using IMRT instead of 3DCRT in PPRT. … (more)
- Is Part Of:
- Journal of medical imaging and radiation oncology. Volume 60:Issue 1(2016:Feb.)
- Journal:
- Journal of medical imaging and radiation oncology
- Issue:
- Volume 60:Issue 1(2016:Feb.)
- Issue Display:
- Volume 60, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2016-0060-0001-0000
- Page Start:
- 129
- Page End:
- 137
- Publication Date:
- 2015-10-05
- Subjects:
- framework evaluation -- IMRT versus 3DCRT -- modelled outcomes -- post‐prostatectomy radiotherapy -- safety
Radiology, Medical -- Periodicals
Radiology, Medical -- Australasia -- Periodicals
616.0757 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1754-9485 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1754-9485.12390 ↗
- Languages:
- English
- ISSNs:
- 1754-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.072080
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1772.xml