Hepatic reaction dose for parenchymal changes on Gd‐EOB‐DTPA‐enhanced magnetic resonance images after stereotactic body radiation therapy for hepatocellular carcinoma. Issue 1 (27th October 2015)
- Record Type:
- Journal Article
- Title:
- Hepatic reaction dose for parenchymal changes on Gd‐EOB‐DTPA‐enhanced magnetic resonance images after stereotactic body radiation therapy for hepatocellular carcinoma. Issue 1 (27th October 2015)
- Main Title:
- Hepatic reaction dose for parenchymal changes on Gd‐EOB‐DTPA‐enhanced magnetic resonance images after stereotactic body radiation therapy for hepatocellular carcinoma
- Authors:
- Jung, Jinhong
Yoon, Sang Min
Cho, Byungchul
Choi, Young Eun
Kwak, Jungwon
Kim, So Yeon
Lee, Sang‐wook
Ahn, Seung Do
Choi, Eun Kyung
Kim, Jong Hoon - Abstract:
- Abstract: Introduction: The present study evaluated the threshold dose for hepatic parenchymal changes on gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd‐EOB‐DTPA)‐enhanced magnetic resonance (MR) images after stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC). Methods: Twenty patients with available data of follow‐up MR images acquired 2–4 months after completion of SBRT were selected among the registered patients. SBRT was performed using multiple coplanar and non‐coplanar beams with energies of 6 or 15 MV. All patients were treated with doses of 45 Gy administered in three fractions over 3 consecutive days. For image registration between planning computed tomography (CT) and MR images, landmark‐based rigid body registration was performed using MIM software. Results: Seventeen patients were included in the analysis. The median discrepancies between planning CT and MR images in the left–right, anterior–posterior and superior–inferior directions were 1.38 mm, 1.24 mm and 1.72 mm, respectively. The median D50 value for the defect in the hepatobiliary phase of Gd‐EOB‐DTPA‐enhanced MR images after SBRT was 19.8 Gy (range, 14.2–28.7 Gy), with R 2 values ranging from 0.76 to 0.99. Conclusions: The threshold dose for parenchymal changes in the hepatobiliary phase of Gd‐EOB‐DTPA‐enhanced MR images performed 2–4 months after 45 Gy of SBRT in three fractions was approximately 20 Gy. Our results provide the basis for further research on theAbstract: Introduction: The present study evaluated the threshold dose for hepatic parenchymal changes on gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd‐EOB‐DTPA)‐enhanced magnetic resonance (MR) images after stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC). Methods: Twenty patients with available data of follow‐up MR images acquired 2–4 months after completion of SBRT were selected among the registered patients. SBRT was performed using multiple coplanar and non‐coplanar beams with energies of 6 or 15 MV. All patients were treated with doses of 45 Gy administered in three fractions over 3 consecutive days. For image registration between planning computed tomography (CT) and MR images, landmark‐based rigid body registration was performed using MIM software. Results: Seventeen patients were included in the analysis. The median discrepancies between planning CT and MR images in the left–right, anterior–posterior and superior–inferior directions were 1.38 mm, 1.24 mm and 1.72 mm, respectively. The median D50 value for the defect in the hepatobiliary phase of Gd‐EOB‐DTPA‐enhanced MR images after SBRT was 19.8 Gy (range, 14.2–28.7 Gy), with R 2 values ranging from 0.76 to 0.99. Conclusions: The threshold dose for parenchymal changes in the hepatobiliary phase of Gd‐EOB‐DTPA‐enhanced MR images performed 2–4 months after 45 Gy of SBRT in three fractions was approximately 20 Gy. Our results provide the basis for further research on the functional loss of liver parenchyma after SBRT. … (more)
- Is Part Of:
- Journal of medical imaging and radiation oncology. Volume 60:Issue 1(2016:Feb.)
- Journal:
- Journal of medical imaging and radiation oncology
- Issue:
- Volume 60:Issue 1(2016:Feb.)
- Issue Display:
- Volume 60, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2016-0060-0001-0000
- Page Start:
- 96
- Page End:
- 101
- Publication Date:
- 2015-10-27
- Subjects:
- hepatocellular carcinoma -- magnetic resonance image -- stereotactic body radiation therapy
Radiology, Medical -- Periodicals
Radiology, Medical -- Australasia -- Periodicals
616.0757 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1754-9485 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1754-9485.12393 ↗
- Languages:
- English
- ISSNs:
- 1754-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.072080
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1772.xml