Evaluation of the QMS® Teicoplanin Immunoassay (ThermoFisher Scientific) on Cobas® 8000 System (Roche Diagnostics) and Comparison to Fluorescence Polarization Immunoassay for the Determination of Teicoplanin Concentrations in Human Plasma. Issue 2 (1st February 2013)
- Record Type:
- Journal Article
- Title:
- Evaluation of the QMS® Teicoplanin Immunoassay (ThermoFisher Scientific) on Cobas® 8000 System (Roche Diagnostics) and Comparison to Fluorescence Polarization Immunoassay for the Determination of Teicoplanin Concentrations in Human Plasma. Issue 2 (1st February 2013)
- Main Title:
- Evaluation of the QMS® Teicoplanin Immunoassay (ThermoFisher Scientific) on Cobas® 8000 System (Roche Diagnostics) and Comparison to Fluorescence Polarization Immunoassay for the Determination of Teicoplanin Concentrations in Human Plasma
- Authors:
- Dailly, Eric
Fraissinet, François
Deslandes, Guillaume
Bouquié, Régis
Jolliet, Pascale - Abstract:
- Abstract : Background: The performances of the QMS ® Teicoplanin immunoassay recently developed on Cobas ® 6000/8000 systems were evaluated and compared to a fluorescence polarization immunoassay (FPIA) [Teicoplanin Innofluor ® Assay (Thermo Fisher Scientific, Indianapolis, IN)] on FLX analyzer (Abbott Laboratories, Abbott Park, IL)]. Methods: The validation was performed according to the Cofrac (French Accreditation Committee) document SH GTA 04. For the comparison, 48 plasma samples were analyzed by FPIA and QMS assays. Results: The QMS assay is accurate (intra assay and inter assay inaccuracy ≤ 2.4%) and precise (intra assay and inter assay imprecision ≤ 10.2%). A linear relationship [QMS = 1.0319 × FPIA – 2.8518, r 2 = 0.9246 ( P < 0.001)] between FPIA and QMS was found. In the Bland—Altman plots, no systematic bias was found even if QMS results trends to be lower (mean of the ratio QMS concentration/FPIA concentration = 0.91). Conclusion: These results between QMS and FPIA are consistent, which indicates that QMS ® Teicoplanin immunoassay on Cobas ® 8000 System is an alternative to FPIA. J. Clin. Lab. Anal. 27:96–98, 2013. © 2012 Wiley Periodicals, Inc.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 27:Issue 2(2013:Mar.)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 27:Issue 2(2013:Mar.)
- Issue Display:
- Volume 27, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 27
- Issue:
- 2
- Issue Sort Value:
- 2013-0027-0002-0000
- Page Start:
- 96
- Page End:
- 98
- Publication Date:
- 2013-02-01
- Subjects:
- antibiotic -- therapeutic drug monitoring -- FPIA
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.21567 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1229.xml