False‐positive hepatitis C virus serology after placement of a ventricular assistance device. Issue 1 (30th January 2016)
- Record Type:
- Journal Article
- Title:
- False‐positive hepatitis C virus serology after placement of a ventricular assistance device. Issue 1 (30th January 2016)
- Main Title:
- False‐positive hepatitis C virus serology after placement of a ventricular assistance device
- Authors:
- Durand, C.M.
Marr, K.A.
Ostrander, D.
Subramanian, A.
Valsamakis, A.
Cox, A.
Neofytos, D. - Abstract:
- Abstract: Background: Ventricular assist devices (VADs) have been associated with immune activation and sensitization. We observed several cases of false‐positive (FP) hepatitis C virus (HCV) antibody (Ab) tests in patients being evaluated for orthotopic heart transplant (OHT), prompting us to investigate this further. Methods: We reviewed all VAD and OHT cases at Johns Hopkins from 2005 to 2012. FP HCV serology was defined as an equivocal or low‐positive HCV Ab, plus either (i) a negative recombinant immunoblot (RIBA) and/or HCV nucleic acid test (NAT), or (ii) an indeterminate RIBA and negative NAT. Results: In 53 patients with available HCV testing, nearly 40% of patients (21/53: 39.6%) developed FP HCV Ab tests after VAD placement: 4 patients had negative NAT, 12 had negative RIBA, and 5 had an indeterminate RIBA and negative NAT. All patients with indeterminate RIBA tests had isolated reactivity to the same HCV protein, c100p/5‐1‐1p (NS4b protein). In 3 of 4 VAD patients who had OHT and repeat HCV Ab testing after VAD removal, repeat HCV Ab was negative (699–947 days after OHT); in 1 case, FP HCV serology persisted (5 days after OHT). Thirteen patients had OHT alone and none developed a FP HCV Ab. Conclusions: FP HCV Ab results following VAD placement are very common. Reversal of FP serology in several patients after VAD removal is suggestive of a possible association with the VAD hardware. Clinicians should be aware of this phenomenon, as it could lead to delays inAbstract: Background: Ventricular assist devices (VADs) have been associated with immune activation and sensitization. We observed several cases of false‐positive (FP) hepatitis C virus (HCV) antibody (Ab) tests in patients being evaluated for orthotopic heart transplant (OHT), prompting us to investigate this further. Methods: We reviewed all VAD and OHT cases at Johns Hopkins from 2005 to 2012. FP HCV serology was defined as an equivocal or low‐positive HCV Ab, plus either (i) a negative recombinant immunoblot (RIBA) and/or HCV nucleic acid test (NAT), or (ii) an indeterminate RIBA and negative NAT. Results: In 53 patients with available HCV testing, nearly 40% of patients (21/53: 39.6%) developed FP HCV Ab tests after VAD placement: 4 patients had negative NAT, 12 had negative RIBA, and 5 had an indeterminate RIBA and negative NAT. All patients with indeterminate RIBA tests had isolated reactivity to the same HCV protein, c100p/5‐1‐1p (NS4b protein). In 3 of 4 VAD patients who had OHT and repeat HCV Ab testing after VAD removal, repeat HCV Ab was negative (699–947 days after OHT); in 1 case, FP HCV serology persisted (5 days after OHT). Thirteen patients had OHT alone and none developed a FP HCV Ab. Conclusions: FP HCV Ab results following VAD placement are very common. Reversal of FP serology in several patients after VAD removal is suggestive of a possible association with the VAD hardware. Clinicians should be aware of this phenomenon, as it could lead to delays in determining eligibility for OHT and increased costs. … (more)
- Is Part Of:
- Transplant infectious disease. Volume 18:Issue 1(2016)
- Journal:
- Transplant infectious disease
- Issue:
- Volume 18:Issue 1(2016)
- Issue Display:
- Volume 18, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 18
- Issue:
- 1
- Issue Sort Value:
- 2016-0018-0001-0000
- Page Start:
- 146
- Page End:
- 149
- Publication Date:
- 2016-01-30
- Subjects:
- left ventricular assist device -- false‐positive hepatitis C virus serology -- orthotopic heart transplant -- sensitization -- panel reactive antibodies
Transplantation of organs, tissues, etc -- Complications -- Periodicals
Communicable diseases -- Periodicals
Infection -- Periodicals
617.01 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=mid ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/tid.12483 ↗
- Languages:
- English
- ISSNs:
- 1398-2273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9024.988700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1970.xml