Introduction of a closed‐system cell processor for red blood cell washing: postimplementation monitoring of safety and efficacy. Issue 1 (7th October 2015)
- Record Type:
- Journal Article
- Title:
- Introduction of a closed‐system cell processor for red blood cell washing: postimplementation monitoring of safety and efficacy. Issue 1 (7th October 2015)
- Main Title:
- Introduction of a closed‐system cell processor for red blood cell washing: postimplementation monitoring of safety and efficacy
- Authors:
- Acker, Jason P.
Hansen, Adele L.
Yi, Qi‐Long
Sondi, Nayana
Cserti‐Gazdewich, Christine
Pendergrast, Jacob
Hannach, Barbara - Abstract:
- Abstract : BACKGROUND: After introduction of a closed‐system cell processor, the effect of this product change on safety, efficacy, and utilization of washed red blood cells (RBCs) was assessed. STUDY DESIGN AND METHODS: This study was a pre‐/postimplementation observational study. Efficacy data were collected from sequentially transfused washed RBCs received as prophylactic therapy by β‐thalassemia patients during a 3‐month period before and after implementation of the Haemonetics ACP 215 closed‐system processor. Before implementation, an open system (TerumoBCT COBE 2991) was used to wash RBCs. The primary endpoint for efficacy was a change in hemoglobin (Hb) concentration corrected for the duration between transfusions. The primary endpoint for safety was the frequency of adverse transfusion reactions (ATRs) in all washed RBCs provided by Canadian Blood Services to the transfusion service for 12 months before and after implementation. RESULTS: Data were analyzed from more than 300 RBCs transfused to 31 recipients before implementation and 29 recipients after implementation. The number of units transfused per episode reduced significantly after implementation, from a mean of 3.5 units to a mean of 3.1 units (p < 0.005). The corrected change in Hb concentration was not significantly different before and after implementation. ATRs occurred in 0.15% of transfusions both before and after implementation. CONCLUSION: Safety and efficacy of washed RBCs were not affected afterAbstract : BACKGROUND: After introduction of a closed‐system cell processor, the effect of this product change on safety, efficacy, and utilization of washed red blood cells (RBCs) was assessed. STUDY DESIGN AND METHODS: This study was a pre‐/postimplementation observational study. Efficacy data were collected from sequentially transfused washed RBCs received as prophylactic therapy by β‐thalassemia patients during a 3‐month period before and after implementation of the Haemonetics ACP 215 closed‐system processor. Before implementation, an open system (TerumoBCT COBE 2991) was used to wash RBCs. The primary endpoint for efficacy was a change in hemoglobin (Hb) concentration corrected for the duration between transfusions. The primary endpoint for safety was the frequency of adverse transfusion reactions (ATRs) in all washed RBCs provided by Canadian Blood Services to the transfusion service for 12 months before and after implementation. RESULTS: Data were analyzed from more than 300 RBCs transfused to 31 recipients before implementation and 29 recipients after implementation. The number of units transfused per episode reduced significantly after implementation, from a mean of 3.5 units to a mean of 3.1 units (p < 0.005). The corrected change in Hb concentration was not significantly different before and after implementation. ATRs occurred in 0.15% of transfusions both before and after implementation. CONCLUSION: Safety and efficacy of washed RBCs were not affected after introduction of a closed‐system cell processor. The ACP 215 allowed for an extended expiry time, improving inventory management and overall utilization of washed RBCs. Transfusion of fewer RBCs per episode reduced exposure of recipients to allogeneic blood products while maintaining efficacy. … (more)
- Is Part Of:
- Transfusion. Volume 56:Issue 1(2016:Feb.)
- Journal:
- Transfusion
- Issue:
- Volume 56:Issue 1(2016:Feb.)
- Issue Display:
- Volume 56, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 56
- Issue:
- 1
- Issue Sort Value:
- 2015-0056-0001-0000
- Page Start:
- 49
- Page End:
- 57
- Publication Date:
- 2015-10-07
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.13341 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2635.xml