In vivo biocompatibility of boron doped and nitrogen included conductive‐diamond for use in medical implants. (21st January 2015)
- Record Type:
- Journal Article
- Title:
- In vivo biocompatibility of boron doped and nitrogen included conductive‐diamond for use in medical implants. (21st January 2015)
- Main Title:
- In vivo biocompatibility of boron doped and nitrogen included conductive‐diamond for use in medical implants
- Authors:
- Garrett, David J.
Saunders, Alexia L.
McGowan, Ceara
Specks, Joscha
Ganesan, Kumaravelu
Meffin, Hamish
Williams, Richard A.
Nayagam, David A.X. - Abstract:
- Abstract: Recently, there has been interest in investigating diamond as a material for use in biomedical implants. Diamond can be rendered electrically conducting by doping with boron or nitrogen. This has led to inclusion of boron doped and nitrogen included diamond elements as electrodes and/or feedthroughs for medical implants. As these conductive device elements are not encapsulated, there is a need to establish their clinical safety for use in implants. This article compares the biocompatibility of electrically conducting boron doped diamond (BDD) and nitrogen included diamond films and electrically insulating poly crystalline diamond films against a silicone negative control and a BDD sample treated with stannous octoate as a positive control. Samples were surgically implanted into the back muscle of a guinea pig for a period of 4–15 weeks, excised and the implant site sectioned and submitted for histological analysis. All forms of diamond exhibited a similar or lower thickness of fibrotic tissue encapsulating compared to the silicone negative control samples. All forms of diamond exhibited similar or lower levels of acute, chronic inflammatory, and foreign body responses compared to the silicone negative control indicating that the materials are well tolerated in vivo . © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 19–26, 2016.
- Is Part Of:
- Software testing, verification & reliability. Volume 26:Number 1(2016)
- Journal:
- Software testing, verification & reliability
- Issue:
- Volume 26:Number 1(2016)
- Issue Display:
- Volume 26, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 26
- Issue:
- 1
- Issue Sort Value:
- 2016-0026-0001-0000
- Page Start:
- 19
- Page End:
- 26
- Publication Date:
- 2015-01-21
- Subjects:
- implant design -- in vivo -- nanomodified surfaces -- neural prosthesis -- biocompatibility/soft tissue
Computer software -- Testing -- Periodicals
Computer software -- Verification -- Periodicals
Computer software -- Reliability -- Periodicals
005.14 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jbm.b.33331 ↗
- Languages:
- English
- ISSNs:
- 0960-0833
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8321.457500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1706.xml