Performance evaluation of the Sysmex XN‐1000 hematology analyzer in assessment of the white blood cell count differential in pediatric specimens. (26th September 2015)
- Record Type:
- Journal Article
- Title:
- Performance evaluation of the Sysmex XN‐1000 hematology analyzer in assessment of the white blood cell count differential in pediatric specimens. (26th September 2015)
- Main Title:
- Performance evaluation of the Sysmex XN‐1000 hematology analyzer in assessment of the white blood cell count differential in pediatric specimens
- Authors:
- Becker, P.‐H.
Fenneteau, O.
Da Costa, L. - Abstract:
- Abstract: Introduction: The automated XN‐1000 hematology analyzer enables to perform a blood cell count and a leukocyte differential. When abnormal cells were detected, a flag was generated by the analyzer and a manual microscopic examination of the corresponding blood film was performed. Methods: We compared the white blood cell differentials provided by the automated hematology analyzer XN‐1000 in a pediatric population ( n = 765) with those obtained through microscopic examination by cytologists and those obtained using a previous version of this analyzer, the XE‐2100. Leukocytes count as well as flags sensitivity and specificity was analyzed. Results: The leukocytes count provided by the analyzer is in good accordance with the differential obtained by manual count in children older than 3 months. The sensitivity for blast detection is 99% and the detection of reactive cells is 63%. The flag specificity remains low (<35%) for blood samples collected from infants between 8 days and 2 years of age, but increases up to 67% thereafter. The results obtained with the XN‐1000 analyzer show an improvement in comparison with those obtained with the XE‐2100 analyzer. Conclusion: The automated WBC differential provided by the XN‐1000 analyzer in the pediatric setting is accurate, but a meticulous microscopic examination of blood smears remains necessary for infants up to 3 months of age to validate the analyzer flags.
- Is Part Of:
- International journal of laboratory hematology. Volume 38:Number 1(2016:Feb.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 38:Number 1(2016:Feb.)
- Issue Display:
- Volume 38, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2016-0038-0001-0000
- Page Start:
- 54
- Page End:
- 63
- Publication Date:
- 2015-09-26
- Subjects:
- Automated blood cells analyzers -- WBC differentials -- pediatrics -- Sysmex XN‐1000 -- flags
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12436 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 378.xml