Efficient automated syntheses of high specific activity 6‐[18F]fluorodopamine using a diaryliodonium salt precursor1. (23rd December 2015)
- Record Type:
- Journal Article
- Title:
- Efficient automated syntheses of high specific activity 6‐[18F]fluorodopamine using a diaryliodonium salt precursor1. (23rd December 2015)
- Main Title:
- Efficient automated syntheses of high specific activity 6‐[18F]fluorodopamine using a diaryliodonium salt precursor1
- Authors:
- Neumann, Kiel D.
Qin, Linlin
Vāvere, Amy L.
Shen, Bin
Miao, Zheng
Chin, Frederick T.
Shulkin, Barry L.
Snyder, Scott E.
DiMagno, Stephen G. - Abstract:
- Abstract : 6‐[ 18 F]Fluorodopamine (6‐[ 18 F]F‐DA) is a positron emission tomography radiopharmaceutical used to image sympathetic cardiac innervation and neuroendocrine tumors. Imaging with 6‐[ 18 F]F‐DA is constrained, in part, by the bioactivity and neurotoxicity of 6‐[ 19 F]fluorodopamine. Furthermore, routine access to this radiotracer is limited by the inherent difficulty of incorporation of [ 18 F]fluoride into electron‐rich aromatic substrates. We describe the simple and direct preparation of high specific activity (SA) 6‐[ 18 F]F‐DA from no‐carrier‐added (n.c.a.) [ 18 F]fluoride. Incorporation of n.c.a. [ 18 F]fluoride into a diaryliodonium salt precursor was achieved in 50–75% radiochemical yields (decay corrected to end of bombardment). Synthesis of 6‐[ 18 F]F‐DA on the IBA Synthera® and GE TRACERlab FX‐FN automated platforms gave 6‐[ 18 F]F‐DA in >99% chemical and radiochemical purities after HPLC purification. The final non‐corrected yields of 6‐[ 18 F]F‐DA were 25 ± 4% ( n = 4, 65 min) and 31 ± 6% ( n = 3, 75 min) using the Synthera and TRACERlab modules, respectively. Efficient access to high SA 6‐[ 18 F]F‐DA from a diaryliodonium salt precursor and n.c.a. [ 18 F]fluoride is provided by a relatively subtle change in reaction conditions – replacement of a polar aprotic solvent (acetonitrile) with a relatively nonpolar solvent (toluene) during the critical radiofluorination reaction. Implementation of this process on common radiochemistry platforms should makeAbstract : 6‐[ 18 F]Fluorodopamine (6‐[ 18 F]F‐DA) is a positron emission tomography radiopharmaceutical used to image sympathetic cardiac innervation and neuroendocrine tumors. Imaging with 6‐[ 18 F]F‐DA is constrained, in part, by the bioactivity and neurotoxicity of 6‐[ 19 F]fluorodopamine. Furthermore, routine access to this radiotracer is limited by the inherent difficulty of incorporation of [ 18 F]fluoride into electron‐rich aromatic substrates. We describe the simple and direct preparation of high specific activity (SA) 6‐[ 18 F]F‐DA from no‐carrier‐added (n.c.a.) [ 18 F]fluoride. Incorporation of n.c.a. [ 18 F]fluoride into a diaryliodonium salt precursor was achieved in 50–75% radiochemical yields (decay corrected to end of bombardment). Synthesis of 6‐[ 18 F]F‐DA on the IBA Synthera® and GE TRACERlab FX‐FN automated platforms gave 6‐[ 18 F]F‐DA in >99% chemical and radiochemical purities after HPLC purification. The final non‐corrected yields of 6‐[ 18 F]F‐DA were 25 ± 4% ( n = 4, 65 min) and 31 ± 6% ( n = 3, 75 min) using the Synthera and TRACERlab modules, respectively. Efficient access to high SA 6‐[ 18 F]F‐DA from a diaryliodonium salt precursor and n.c.a. [ 18 F]fluoride is provided by a relatively subtle change in reaction conditions – replacement of a polar aprotic solvent (acetonitrile) with a relatively nonpolar solvent (toluene) during the critical radiofluorination reaction. Implementation of this process on common radiochemistry platforms should make 6‐[ 18 F]F‐DA readily available to the wider imaging community. Abstract : 6‐[ 18 F]Fluorodopamine (6‐[ 18 F]F‐DA) is a positron emission tomography radiopharmaceutical used to image sympathetic cardiac innervation and neuroendocrine tumors. Imaging with 6‐[ 18 F]F‐DA is limited by the difficulty of late‐stage incorporation of [ 18 F]fluoride into electron‐rich aromatic substrates. We report that the fully automated synthesis of 6‐[ 18 F]F‐DA on the IBA Synthera® and GE TRACERlab FX‐FN automated platforms in non‐corrected yields of [ 18 F]F‐DA was 25 ± 4% ( n = 4; 65 min) and 31 ± 6% ( n = 3; 75 min) using the Synthera and TRACERlab modules, respectively. … (more)
- Is Part Of:
- Journal of labelled compounds & radiopharmaceuticals. Volume 59:Number 1(2016)
- Journal:
- Journal of labelled compounds & radiopharmaceuticals
- Issue:
- Volume 59:Number 1(2016)
- Issue Display:
- Volume 59, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 59
- Issue:
- 1
- Issue Sort Value:
- 2015-0059-0001-0000
- Page Start:
- 30
- Page End:
- 34
- Publication Date:
- 2015-12-23
- Subjects:
- 6‐[18F]fluorodopamine -- positron emission tomography -- emission computed tomography -- diaryliodonium salts -- fluorine‐18
Tracers (Chemistry) -- Periodicals
Radiopharmaceuticals -- Periodicals
615.8424 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jlcr.3367 ↗
- Languages:
- English
- ISSNs:
- 0362-4803
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5009.910000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2013.xml