Discovery of a solvent effect preventing quantitative profiling by matrix‐assisted laser desorption/ionization and its treatment. (28th December 2015)
- Record Type:
- Journal Article
- Title:
- Discovery of a solvent effect preventing quantitative profiling by matrix‐assisted laser desorption/ionization and its treatment. (28th December 2015)
- Main Title:
- Discovery of a solvent effect preventing quantitative profiling by matrix‐assisted laser desorption/ionization and its treatment
- Authors:
- Park, Kyung Man
Moon, Jeong Hee
Kim, Jae Hyung
Song, Un Tak
Lee, Seong Hoon
Kim, Myung Soo - Abstract:
- Abstract : Rationale: In analyte profiling by matrix‐assisted laser desorption/ionization (MALDI), drawing a quantitative profile map is an outstanding problem. Recently, we developed a method to quantify an analyte by MALDI, which is needed to solve the problem. Another requirement for quantitative profiling is the quantitative sample‐to‐matrix analyte transfer, which is investigated in this work. Methods: MALDI‐time‐of‐flight (TOF) spectra were acquired for samples produced by two methods. In one, a sample solution containing a matrix and an analyte was loaded with a pipet and dried. In the other, a sample was prepared by a consecutive process, i.e., loading‐drying of an analyte solution followed by that of a matrix solution. Two different micro‐spotters were used in the second method. Various mixtures of organic solvents with water were used to prepare matrix solutions. Results: The organic solvent, matrix, and analyte used in the study did not affect the analyte transfer efficiency, whereas it improved as the water content in the solvent increased. It also improved as the liquid droplet emitted by a micro‐spotter got larger. Use of a more polar solvent or a larger droplet increases the contact time between a solution droplet and the sample surface, which seems to be responsible for the improvement in the transfer efficiency. Conclusions: Sample‐to‐matrix analyte transfer occurred efficiently when polar solvents and/or large liquid droplets were used to produce solidAbstract : Rationale: In analyte profiling by matrix‐assisted laser desorption/ionization (MALDI), drawing a quantitative profile map is an outstanding problem. Recently, we developed a method to quantify an analyte by MALDI, which is needed to solve the problem. Another requirement for quantitative profiling is the quantitative sample‐to‐matrix analyte transfer, which is investigated in this work. Methods: MALDI‐time‐of‐flight (TOF) spectra were acquired for samples produced by two methods. In one, a sample solution containing a matrix and an analyte was loaded with a pipet and dried. In the other, a sample was prepared by a consecutive process, i.e., loading‐drying of an analyte solution followed by that of a matrix solution. Two different micro‐spotters were used in the second method. Various mixtures of organic solvents with water were used to prepare matrix solutions. Results: The organic solvent, matrix, and analyte used in the study did not affect the analyte transfer efficiency, whereas it improved as the water content in the solvent increased. It also improved as the liquid droplet emitted by a micro‐spotter got larger. Use of a more polar solvent or a larger droplet increases the contact time between a solution droplet and the sample surface, which seems to be responsible for the improvement in the transfer efficiency. Conclusions: Sample‐to‐matrix analyte transfer occurred efficiently when polar solvents and/or large liquid droplets were used to produce solid samples for MALDI profiling with a micro‐spotter. A long contact time between the sample surface and a matrix solution droplet is one of the requirements for quantitative profiling. Copyright © 2015 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 30:Number 3(2016)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 30:Number 3(2016)
- Issue Display:
- Volume 30, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2016-0030-0003-0000
- Page Start:
- 386
- Page End:
- 392
- Publication Date:
- 2015-12-28
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7452 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 313.xml