Vagus Nerve Stimulator Placement in Dogs: Surgical Implantation Technique, Complications, Long‐Term Follow‐Up, and Practical Considerations. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- Vagus Nerve Stimulator Placement in Dogs: Surgical Implantation Technique, Complications, Long‐Term Follow‐Up, and Practical Considerations. Issue 1 (January 2016)
- Main Title:
- Vagus Nerve Stimulator Placement in Dogs: Surgical Implantation Technique, Complications, Long‐Term Follow‐Up, and Practical Considerations
- Authors:
- Martlé, Valentine
Van Ham, Luc M. L.
Boon, Paul
Caemaert, Jacques
Tshamala, Mulenda
Vonck, Kristl
Raedt, Robrecht
Polis, Ingeborgh
Bhatti, Sofie - Abstract:
- Abstract : Objective: To describe a modified implantation procedure of a vagus nerve stimulation (VNS) device in dogs and to report short‐ and long‐term complications. Study Design: Descriptive, experimental study. Animals: Healthy, adult Beagle dogs (n = 10). Methods: A VNS Therapy ® System was implanted in the left cervical region of anesthetized dogs. During and within 48 hours after surgery, electrocardiography (ECG) and impedance testing of the system were performed. Dogs were monitored daily and the impedance of the system was determined regularly until VNS devices were surgically removed 3 years after implantation. Results: The implantation procedure was successful in all dogs without intraoperative complications. ECG monitoring and impedance tests were within normal limits during and within 48 hours after surgery. Postoperative seroma formation was common (70%). One dog developed an irreversible Horner's syndrome leading to removal of the device 5 months after implantation. Another dog developed trauma‐induced damage of the lead requiring surgical revision. The device could be safely removed in all dogs; however, electrodes were left in place to avoid nerve damage. At removal, the anchor tether was dislodged in 40% of dogs and the lead was twisted in 50% of dogs. Conclusion: Implantation of a VNS Therapy ® System is safe and feasible in dogs; however, seroma formation, twisting of the lead, and dislodgement of the anchor tether were common. Practical improvements inAbstract : Objective: To describe a modified implantation procedure of a vagus nerve stimulation (VNS) device in dogs and to report short‐ and long‐term complications. Study Design: Descriptive, experimental study. Animals: Healthy, adult Beagle dogs (n = 10). Methods: A VNS Therapy ® System was implanted in the left cervical region of anesthetized dogs. During and within 48 hours after surgery, electrocardiography (ECG) and impedance testing of the system were performed. Dogs were monitored daily and the impedance of the system was determined regularly until VNS devices were surgically removed 3 years after implantation. Results: The implantation procedure was successful in all dogs without intraoperative complications. ECG monitoring and impedance tests were within normal limits during and within 48 hours after surgery. Postoperative seroma formation was common (70%). One dog developed an irreversible Horner's syndrome leading to removal of the device 5 months after implantation. Another dog developed trauma‐induced damage of the lead requiring surgical revision. The device could be safely removed in all dogs; however, electrodes were left in place to avoid nerve damage. At removal, the anchor tether was dislodged in 40% of dogs and the lead was twisted in 50% of dogs. Conclusion: Implantation of a VNS Therapy ® System is safe and feasible in dogs; however, seroma formation, twisting of the lead, and dislodgement of the anchor tether were common. Practical improvements in the technique include stable device placement, use of a compression bandage, and exercise restriction. Regular evaluation of lead impedance is important, as altered values can indicate serious complications. … (more)
- Is Part Of:
- Veterinary surgery. Volume 45:Issue 1(2016)
- Journal:
- Veterinary surgery
- Issue:
- Volume 45:Issue 1(2016)
- Issue Display:
- Volume 45, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 45
- Issue:
- 1
- Issue Sort Value:
- 2016-0045-0001-0000
- Page Start:
- 71
- Page End:
- 78
- Publication Date:
- 2016-01
- Subjects:
- Veterinary surgery -- Periodicals
Veterinary Medicine -- Periodicals
Surgery -- Periodicals
Societies, Medical -- Periodicals
636.0897 - Journal URLs:
- http://www.blackwell-synergy.com/loi/vsu ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=vsu ↗
http://www.harcourthealth.com/vetsurg ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0161-3499;screen=info;ECOIP ↗ - DOI:
- 10.1111/vsu.12427 ↗
- Languages:
- English
- ISSNs:
- 0161-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9231.037000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2052.xml