Evaluation of compliance with electronic pretransfusion check for blood administration at the bedside: a 10·5‐year experience at a university hospital. (30th July 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of compliance with electronic pretransfusion check for blood administration at the bedside: a 10·5‐year experience at a university hospital. (30th July 2015)
- Main Title:
- Evaluation of compliance with electronic pretransfusion check for blood administration at the bedside: a 10·5‐year experience at a university hospital
- Authors:
- Ohsaka, A.
Ohsawa, T.
Nakamura, Y.
Tokida, M.
Ichikawa, K.
Furuta, Y. - Abstract:
- Abstract : Background: The objective of this study was to evaluate compliance with the electronic pretransfusion check for blood administration at the bedside over a 10·5‐year period. Study Design and Methods: A bar code‐based electronic identification system (EIS) has been fully implemented in the hospital. Between July 2002 and December 2012, we evaluated compliance with the electronic pretransfusion check at the bedside. Compliance with our transfusion policy was defined based on the time lag between performing the electronic pretransfusion check and initiating blood administration. Results: A total of 114 855 blood components were transfused without a single mistransfusion, of which the number with a standard two‐person visual and verbal double check but without using the EIS was 2122, resulting in an overall compliance rate with the electronic pretransfusion check of 98·2%. The time lag on inpatient wards and in operating rooms was significantly longer than that in outpatient units. The rate of a time lag with more than 'plus or minus 2 min' (poor compliance) was reduced by the education and retraining regarding the EIS of healthcare professionals. Conclusion: The EIS should be used while monitoring compliance with transfusion practice.
- Is Part Of:
- ISBT science series. Volume 10:Number 2(2015)
- Journal:
- ISBT science series
- Issue:
- Volume 10:Number 2(2015)
- Issue Display:
- Volume 10, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2015-0010-0002-0000
- Page Start:
- 65
- Page End:
- 72
- Publication Date:
- 2015-07-30
- Subjects:
- compliance -- electronic identification system -- pretransfusion check -- transfusion safety
Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-2824 ↗
http://www.blackwell-synergy.com/loi/voxs ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/voxs.12187 ↗
- Languages:
- English
- ISSNs:
- 1751-2816
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4582.773100
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: