QT dynamics evaluated on fully automated QT measurement in children. Issue 6 (5th November 2015)
- Record Type:
- Journal Article
- Title:
- QT dynamics evaluated on fully automated QT measurement in children. Issue 6 (5th November 2015)
- Main Title:
- QT dynamics evaluated on fully automated QT measurement in children
- Authors:
- Takahashi, Kazuhiro
Nabeshima, Taisuke
Sashinami, Arata
Nakayashiro, Mami
Ganaha, Hitoshi - Abstract:
- Abstract: Background: The association between QT interval and heart rate (HR), QT dynamics, has been reported to vary greatly between individuals. We investigated QT dynamics using fully automated QT interval measurement with a commercially available multifunctional electrocardiogram (ECG) recorder. Methods: The study group included 17 otherwise healthy subjects (mean age, 12.7 years; 11 girls, 6 boys), who were undergoing exercise test for arrhythmia evaluation. The subjects had single premature ventricular contraction. Results: Mean corrected QT interval (Fridericia) at rest was 412 ± 19 ms (male, 408 ± 20 ms; female, 414 ± 19 ms), manually measured with a digitizer, using the tangent method. We assessed QT interval/HR slope during the whole exercise test, the exercise phase, and the recovery from exercise phase; the slopes were calculated offline after excluding wide QRS complex and were −1.15 ± 0.26 (r 2 = 0.65), −1.18 ± 0.30 (r 2 = 0.62), and −1.11 ± 0.25 (r 2 = 0.70), respectively. Estimated QT interval at HR 60 beats/min (QT60 ) was calculated using the regression line formula and was 383 ± 24 ms, 387 ± 28 ms, and 375 ± 21 ms, respectively. QT60 of the total exercise test correlated with the corrected QT interval at rest ( P = 0.04, r 2 = 0.25). Conclusions: Assessment of QT dynamics is feasible on fully automated QT interval measurement with this ECG recorder. Further studies are required in larger populations to confirm the accuracy and precision of QTAbstract: Background: The association between QT interval and heart rate (HR), QT dynamics, has been reported to vary greatly between individuals. We investigated QT dynamics using fully automated QT interval measurement with a commercially available multifunctional electrocardiogram (ECG) recorder. Methods: The study group included 17 otherwise healthy subjects (mean age, 12.7 years; 11 girls, 6 boys), who were undergoing exercise test for arrhythmia evaluation. The subjects had single premature ventricular contraction. Results: Mean corrected QT interval (Fridericia) at rest was 412 ± 19 ms (male, 408 ± 20 ms; female, 414 ± 19 ms), manually measured with a digitizer, using the tangent method. We assessed QT interval/HR slope during the whole exercise test, the exercise phase, and the recovery from exercise phase; the slopes were calculated offline after excluding wide QRS complex and were −1.15 ± 0.26 (r 2 = 0.65), −1.18 ± 0.30 (r 2 = 0.62), and −1.11 ± 0.25 (r 2 = 0.70), respectively. Estimated QT interval at HR 60 beats/min (QT60 ) was calculated using the regression line formula and was 383 ± 24 ms, 387 ± 28 ms, and 375 ± 21 ms, respectively. QT60 of the total exercise test correlated with the corrected QT interval at rest ( P = 0.04, r 2 = 0.25). Conclusions: Assessment of QT dynamics is feasible on fully automated QT interval measurement with this ECG recorder. Further studies are required in larger populations to confirm the accuracy and precision of QT measurement and QT dynamics using this new multifunctional ECG. … (more)
- Is Part Of:
- Pediatrics international. Volume 57:Issue 6(2015)
- Journal:
- Pediatrics international
- Issue:
- Volume 57:Issue 6(2015)
- Issue Display:
- Volume 57, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 57
- Issue:
- 6
- Issue Sort Value:
- 2015-0057-0006-0000
- Page Start:
- 1067
- Page End:
- 1071
- Publication Date:
- 2015-11-05
- Subjects:
- arrhythmia -- automated measurement -- heart rate -- QT dynamics -- ventricular contraction
Pediatrics -- Periodicals
618.92 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1442-200X/issues. Subscription to online journal required for access to full text. ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ped.12734 ↗
- Languages:
- English
- ISSNs:
- 1328-8067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.655800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 815.xml