Establishment and Evaluation of a One‐Step Microplate Chemiluminescence Immunoassay to Detect IgG Antibody Against Treponema Pallidum. Issue 6 (2nd October 2014)
- Record Type:
- Journal Article
- Title:
- Establishment and Evaluation of a One‐Step Microplate Chemiluminescence Immunoassay to Detect IgG Antibody Against Treponema Pallidum. Issue 6 (2nd October 2014)
- Main Title:
- Establishment and Evaluation of a One‐Step Microplate Chemiluminescence Immunoassay to Detect IgG Antibody Against Treponema Pallidum
- Authors:
- Liu, Lijuan
Xie, Yuling
Dai, Zhenxian
Zhuo, Chuanshang
Wu, Yushui - Abstract:
- Abstract : Background: The serological detection of specific antibodies against Treponema pallidum is of particular importance in the diagnosis of syphilis. The chemiluminescence immunoassay (CLIA) has been widely used for clinical diagnosis because they remit no radical waste products, cause no enzyme precipitation, and exhibit an excellent sensitivity. Methods: A one‐step CLIA was established to detect T. pallidum IgG antibody based on microplate coated with a mixture of recombinant T. pallidum antigens TpN15, TpN17, and TpN47. The Chinese national reference substances standard panel for T. pallidum diagnosis was applied to test the accuracy, stability, interference, and cross‐reactivity of the established CLIA. The validation of efficacy for clinical application was performed by comparing the established method with the marketed T. pallidum particle agglutination (TPPA) kit and the Abbott ARCHITEC Auto System. Results: The established method met the requirement of the Chinese national reference substances standard for T. pallidum diagnosis. When compared with TPPA ( n = 1, 052), the specificity, sensitivity, and overall concordance were 99.7%, 99.0%, and 98.8% respectively, showing a great agreement with a kappa value of 0.81. When compared with the Abbott ARCHITEC Auto System ( n = 352), the results showed that the specificity, sensitivity, and overall concordance were 98.6.0%, 96.6% and 98.6% respectively, and a high‐degree agreement was observed (kappa value = 0.95).Abstract : Background: The serological detection of specific antibodies against Treponema pallidum is of particular importance in the diagnosis of syphilis. The chemiluminescence immunoassay (CLIA) has been widely used for clinical diagnosis because they remit no radical waste products, cause no enzyme precipitation, and exhibit an excellent sensitivity. Methods: A one‐step CLIA was established to detect T. pallidum IgG antibody based on microplate coated with a mixture of recombinant T. pallidum antigens TpN15, TpN17, and TpN47. The Chinese national reference substances standard panel for T. pallidum diagnosis was applied to test the accuracy, stability, interference, and cross‐reactivity of the established CLIA. The validation of efficacy for clinical application was performed by comparing the established method with the marketed T. pallidum particle agglutination (TPPA) kit and the Abbott ARCHITEC Auto System. Results: The established method met the requirement of the Chinese national reference substances standard for T. pallidum diagnosis. When compared with TPPA ( n = 1, 052), the specificity, sensitivity, and overall concordance were 99.7%, 99.0%, and 98.8% respectively, showing a great agreement with a kappa value of 0.81. When compared with the Abbott ARCHITEC Auto System ( n = 352), the results showed that the specificity, sensitivity, and overall concordance were 98.6.0%, 96.6% and 98.6% respectively, and a high‐degree agreement was observed (kappa value = 0.95). Conclusion: The established rapid, specific, sensitive, and stable microplate CLIA method to detect IgG antibody against T pallidum will provide an efficient alternative to the treponemal tests and wide application in clinical laboratory. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 29:Issue 6(2015)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 29:Issue 6(2015)
- Issue Display:
- Volume 29, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 6
- Issue Sort Value:
- 2015-0029-0006-0000
- Page Start:
- 493
- Page End:
- 497
- Publication Date:
- 2014-10-02
- Subjects:
- Treponema pallidum -- chemiluminescence -- antibody -- IgG -- diagnosis
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.21799 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1792.xml