Constable, P.D. - Abstract:
- Abstract : Background: The Precision Xtra ® meter is a promising low cost electrochemical point‐of‐care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra‐erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. Objectives: The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. Animals: A total of 106 periparturient Holstein‐Friesian cattle. Methods: Blood and plasma samples (1, 109) were obtained and Deming regression and Bland–Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Results: Intra‐erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. Conclusions and clinical importance: The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle‐specific algorithm is developed, we recommend using plasma as the analyteAbstract : Background: The Precision Xtra ® meter is a promising low cost electrochemical point‐of‐care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra‐erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. Objectives: The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. Animals: A total of 106 periparturient Holstein‐Friesian cattle. Methods: Blood and plasma samples (1, 109) were obtained and Deming regression and Bland–Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Results: Intra‐erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. Conclusions and clinical importance: The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle‐specific algorithm is developed, we recommend using plasma as the analyte instead of blood and calculating plasma [gluc] using the equation: [gluc] = 0.66 × [gluc]p‐meter + 15, where [gluc]p‐meter is the value reported by the meter. If blood is measured, then we recommend using the equation: [gluc] = 0.90 × [gluc]b‐meter + 15. … (more)
- Is Part Of:
- Journal of veterinary internal medicine. Volume 29:Number 6(2015:Nov./Dec.)
- Journal:
- Journal of veterinary internal medicine
- Issue:
- Volume 29:Number 6(2015:Nov./Dec.)
- Issue Display:
- Volume 29, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 6
- Issue Sort Value:
- 2015-0029-0006-0000
- Page Start:
- 1718
- Page End:
- 1727
- Publication Date:
- 2015-10-20
- Subjects:
- hyperglycemia -- hyperketonemia -- hypoglycemia -- ketosis
Veterinary medicine -- Periodicals
636.0896 - Journal URLs:
- http://www.jvetintmed.org ↗
http://www3.interscience.wiley.com/journal/118902531/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jvim.13608 ↗
- Languages:
- English
- ISSNs:
- 0891-6640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5072.365000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 972.xml