Matrix solid‐phase dispersion coupled with homogeneous ionic liquid microextraction for the determination of sulfonamides in animal tissues using high‐performance liquid chromatography. Issue 23 (6th November 2015)
- Record Type:
- Journal Article
- Title:
- Matrix solid‐phase dispersion coupled with homogeneous ionic liquid microextraction for the determination of sulfonamides in animal tissues using high‐performance liquid chromatography. Issue 23 (6th November 2015)
- Main Title:
- Matrix solid‐phase dispersion coupled with homogeneous ionic liquid microextraction for the determination of sulfonamides in animal tissues using high‐performance liquid chromatography
- Authors:
- Wang, Zhibing
He, Mengyu
Jiang, Chunzhu
Zhang, Fengqing
Du, Shanshan
Feng, Wennan
Zhang, Hanqi - Abstract:
- Abstract : Matrix solid‐phase dispersion coupled with homogeneous ionic liquid microextraction was developed and applied to the extraction of some sulfonamides, including sulfamerazine, sulfamethazine, sulfathiazole, sulfachloropyridazine, sulfadoxine, sulfisoxazole, and sulfaphenazole, in animal tissues. High‐performance liquid chromatography was applied to the separation and determination of the target analytes. The solid sample was directly treated by matrix solid‐phase dispersion and the eluate obtained was treated by homogeneous ionic liquid microextraction. The ionic liquid was used as the extraction solvent in this method, which may result in the improvement of the recoveries of the target analytes. To avoid using organic solvent and reduce environmental pollution, water was used as the elution solvent of matrix solid‐phase dispersion. The effects of the experimental parameters on recoveries, including the type and volume of ionic liquid, type of dispersant, ratio of sample to dispersant, pH value of elution solvent, volume of elution solvent, amount of salt in eluate, amount of ion‐pairing agent (NH4 PF6 ), and centrifuging time, were evaluated. When the present method was applied to the analysis of animal tissues, the recoveries of the analytes ranged from 85.4 to 118.0%, and the relative standard deviations were lower than 9.30%. The detection limits for the analytes were 4.3–13.4 μg/kg.
- Is Part Of:
- Journal of separation science. Volume 38:Issue 23(2015:Dec.)
- Journal:
- Journal of separation science
- Issue:
- Volume 38:Issue 23(2015:Dec.)
- Issue Display:
- Volume 38, Issue 23 (2015)
- Year:
- 2015
- Volume:
- 38
- Issue:
- 23
- Issue Sort Value:
- 2015-0038-0023-0000
- Page Start:
- 4127
- Page End:
- 4135
- Publication Date:
- 2015-11-06
- Subjects:
- High‐performance liquid chromatography -- Homogeneous ionic liquid microextraction -- Ionic liquids -- Matrix solid‐phase dispersion -- Sulfonamides
Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201500777 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 948.xml