Intervendor Variabilities of Left and Right Ventricular Myocardial Velocities among Three Tissue Doppler Echocardiography Systems. (29th April 2015)
- Record Type:
- Journal Article
- Title:
- Intervendor Variabilities of Left and Right Ventricular Myocardial Velocities among Three Tissue Doppler Echocardiography Systems. (29th April 2015)
- Main Title:
- Intervendor Variabilities of Left and Right Ventricular Myocardial Velocities among Three Tissue Doppler Echocardiography Systems
- Authors:
- Abe, Kiyoshi
Yuda, Satoshi
Sato, Yasumi
Yasui, Kenji
Nishi, Ryosuke
Hanada, Kyosuke
Hashimoto, Naoko
Kawamukai, Mina
Kouzu, Hidemichi
Muranaka, Atsuko
Hashimoto, Akiyoshi
Tsuchihashi, Kazufumi
Watanabe, Naoki
Miura, Tetsuji - Abstract:
- Abstract : Background: Whether an intervendor discordance of myocardial velocities determined by tissue Doppler echocardiography (TDE) can be generalized remains unclear. We compared intervendor variabilities of left ventricular (LV) and right ventricular (RV) myocardial velocities among three TDE systems. Methods: Examinations with TDE were performed in 41 healthy subjects and 11 patients with cardiovascular risk factors (CVR) using α ‐7 (V1, Hitachi Aloka Medical), Artida (V2, Toshiba Medical Systems), and Vivid E9 (V3, GE Healthcare) on the same day. Peak systolic (s′), early diastolic (e′), and late diastolic (a′) myocardial velocities at medial and lateral sites of the mitral annulus and lateral site of the tricuspid annulus were measured using both pulsed‐wave TDE and color TDE. Intra‐observer and inter‐observer variabilities were determined in 10 subjects and test–retest variability in 14 subjects. Results: As for test–retest variability, reproducibilities of LV and RV myocardial velocities determined by pulsed‐wave TDE and color TDE were relatively low but comparable between V1, V2, and V3. Myocardial velocities in healthy subjects determined by both pulsed‐wave TDE and color TDE were significantly different among the three TDE systems. Myocardial velocities by pulsed‐wave TDE in V3 were 2–12% lower (P < 0.05) than those by V2 and 5–14% lower (P < 0.05) than those by V1. Similar differences in myocardial velocities determined by both pulsed‐wave TDE and color TDEAbstract : Background: Whether an intervendor discordance of myocardial velocities determined by tissue Doppler echocardiography (TDE) can be generalized remains unclear. We compared intervendor variabilities of left ventricular (LV) and right ventricular (RV) myocardial velocities among three TDE systems. Methods: Examinations with TDE were performed in 41 healthy subjects and 11 patients with cardiovascular risk factors (CVR) using α ‐7 (V1, Hitachi Aloka Medical), Artida (V2, Toshiba Medical Systems), and Vivid E9 (V3, GE Healthcare) on the same day. Peak systolic (s′), early diastolic (e′), and late diastolic (a′) myocardial velocities at medial and lateral sites of the mitral annulus and lateral site of the tricuspid annulus were measured using both pulsed‐wave TDE and color TDE. Intra‐observer and inter‐observer variabilities were determined in 10 subjects and test–retest variability in 14 subjects. Results: As for test–retest variability, reproducibilities of LV and RV myocardial velocities determined by pulsed‐wave TDE and color TDE were relatively low but comparable between V1, V2, and V3. Myocardial velocities in healthy subjects determined by both pulsed‐wave TDE and color TDE were significantly different among the three TDE systems. Myocardial velocities by pulsed‐wave TDE in V3 were 2–12% lower (P < 0.05) than those by V2 and 5–14% lower (P < 0.05) than those by V1. Similar differences in myocardial velocities determined by both pulsed‐wave TDE and color TDE were found in patients with CVR. Conclusions: LV and RV myocardial velocities determined by both pulsed‐wave TDE and color TDE are vendor dependent, and reproducibility of the myocardial velocities determined by both TDE systems is relatively low. … (more)
- Is Part Of:
- Echocardiography. Volume 32:issue 12(2015:Dec.)
- Journal:
- Echocardiography
- Issue:
- Volume 32:issue 12(2015:Dec.)
- Issue Display:
- Volume 32, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 32
- Issue:
- 12
- Issue Sort Value:
- 2015-0032-0012-0000
- Page Start:
- 1790
- Page End:
- 1801
- Publication Date:
- 2015-04-29
- Subjects:
- tissue Doppler echocardiography -- left ventricular function -- right ventricular function -- myocardial velocity -- reproducibility -- intervendor variability
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12962 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1284.xml