Assessment of the endoscopic range of motion for head and neck surgery using the SOLOASSIST endoscope holder. Issue 4 (1st February 2015)
- Record Type:
- Journal Article
- Title:
- Assessment of the endoscopic range of motion for head and neck surgery using the SOLOASSIST endoscope holder. Issue 4 (1st February 2015)
- Main Title:
- Assessment of the endoscopic range of motion for head and neck surgery using the SOLOASSIST endoscope holder
- Authors:
- Kristin, Julia
Geiger, Robert
Kraus, Peter
Klenzner, Thomas - Abstract:
- Abstract: Background: A 'third hand' is useful for holding the endoscope during surgery. The SOLOASSIST camera holder (AktorMed GmbH, Germany), which is used for abdominal surgery, is supposed to be modified for head and neck surgery. The aim of this study was to determine the intraoperative hand‐held endoscopic range of motion for different surgical procedures and to define the required technical changes. Methods: The intraoperative movements of the hand‐held endoscope during sinus surgery, rigid laryngoscopy, and lateral skull base surgery were measured and calculated. Results: The endoscopic range of motion during surgery revealed diverse geometric bodies and volumes. For use in the ENT area, the system must be expanded by a manual release function for the driven axes and two additional lockable axes at the distal end of the arm. Conclusion: Intraoperative endoscopic range of motions in head and neck surgery are highly specific and, as expected, differ from the endoscopic movements in abdominal surgery. Copyright © 2015 John Wiley & Sons, Ltd.
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 11:Issue 4(2015)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 11:Issue 4(2015)
- Issue Display:
- Volume 11, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 11
- Issue:
- 4
- Issue Sort Value:
- 2015-0011-0004-0000
- Page Start:
- 418
- Page End:
- 423
- Publication Date:
- 2015-02-01
- Subjects:
- endoscope holder -- SOLOASSIST -- mechatronic guidance
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.1643 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1955.xml