Increased speed and image quality in single‐shot fast spin echo imaging via variable refocusing flip angles. Issue 6 (19th June 2015)
- Record Type:
- Journal Article
- Title:
- Increased speed and image quality in single‐shot fast spin echo imaging via variable refocusing flip angles. Issue 6 (19th June 2015)
- Main Title:
- Increased speed and image quality in single‐shot fast spin echo imaging via variable refocusing flip angles
- Authors:
- Loening, Andreas M.
Saranathan, Manojkumar
Ruangwattanapaisarn, Nichanan
Litwiller, Daniel V.
Shimakawa, Ann
Vasanawala, Shreyas S. - Abstract:
- Abstract : Purpose: To develop and validate clinically a single‐shot fast spin echo (SSFSE) sequence utilizing variable flip angle refocusing pulses to shorten acquisition times via reductions in specific absorption rate (SAR) and improve image quality. Materials and Methods: A variable refocusing flip angle SSFSE sequence (vrfSSFSE) was designed and implemented, with simulations and volunteer scans performed to determine suitable flip angle modulation parameters. With Institutional Review Board (IRB) approval/informed consent, patients referred for 3T abdominal magnetic resonance imaging (MRI) were scanned with conventional SSFSE and either half‐Fourier ( n = 25) or full‐Fourier vrfSSFSE ( n = 50). Two blinded radiologists semiquantitatively scored images on a scale from −2 to 2 for contrast, noise, sharpness, artifacts, cardiac motion‐related signal loss, and the ability to evaluate the pancreas and kidneys. Results: vrfSSFSE demonstrated significantly increased speed (∼2‐fold, P < 0.0001). Significant improvements in image quality parameters with full‐Fourier vrfSSFSE included increased contrast, sharpness, and visualization of pancreatic and renal structures with higher bandwidth technique (mean scores 0.37, 0.83, 0.62, and 0.31, respectively, P ≤ 0.001), and decreased image noise and improved visualization of renal structures when used with an equal bandwidth technique (mean scores 0.96 and 0.35, respectively, P < 0.001). Increased cardiac motion‐related signalAbstract : Purpose: To develop and validate clinically a single‐shot fast spin echo (SSFSE) sequence utilizing variable flip angle refocusing pulses to shorten acquisition times via reductions in specific absorption rate (SAR) and improve image quality. Materials and Methods: A variable refocusing flip angle SSFSE sequence (vrfSSFSE) was designed and implemented, with simulations and volunteer scans performed to determine suitable flip angle modulation parameters. With Institutional Review Board (IRB) approval/informed consent, patients referred for 3T abdominal magnetic resonance imaging (MRI) were scanned with conventional SSFSE and either half‐Fourier ( n = 25) or full‐Fourier vrfSSFSE ( n = 50). Two blinded radiologists semiquantitatively scored images on a scale from −2 to 2 for contrast, noise, sharpness, artifacts, cardiac motion‐related signal loss, and the ability to evaluate the pancreas and kidneys. Results: vrfSSFSE demonstrated significantly increased speed (∼2‐fold, P < 0.0001). Significant improvements in image quality parameters with full‐Fourier vrfSSFSE included increased contrast, sharpness, and visualization of pancreatic and renal structures with higher bandwidth technique (mean scores 0.37, 0.83, 0.62, and 0.31, respectively, P ≤ 0.001), and decreased image noise and improved visualization of renal structures when used with an equal bandwidth technique (mean scores 0.96 and 0.35, respectively, P < 0.001). Increased cardiac motion‐related signal loss with full‐Fourier vrfSSFSE was seen in the pancreas but not the kidney. Conclusion: vrfSSFSE increases speed at 3T over conventional SSFSE via reduced SAR, and when combined with full‐Fourier acquisition can improve image quality, although with some increased sensitivity to cardiac motion‐related signal loss. J. MAGN. RESON. IMAGING 2015;42:1747–1758. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 42:Issue 6(2015)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 42:Issue 6(2015)
- Issue Display:
- Volume 42, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 6
- Issue Sort Value:
- 2015-0042-0006-0000
- Page Start:
- 1747
- Page End:
- 1758
- Publication Date:
- 2015-06-19
- Subjects:
- single shot fast spin echo -- variable refocusing flip angle -- specific absorption rate -- echo stabilization
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24941 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 377.xml