Electrode array extrusion through the posterior canal wall presenting as a delayed post-cochlear implant complication. (November 2015)
- Record Type:
- Journal Article
- Title:
- Electrode array extrusion through the posterior canal wall presenting as a delayed post-cochlear implant complication. (November 2015)
- Main Title:
- Electrode array extrusion through the posterior canal wall presenting as a delayed post-cochlear implant complication
- Authors:
- Rangabashyam, Mahalakshmi
Poh, Sharon Shuxian
Low, Wong Kein - Abstract:
- Abstract : Objectives and importance: Cochlear implantation is an established, reliable, and safe procedure with a low complication rate. Electrode array extrusion through the posterior aspect of external ear canal is a potential major complication of cochlear implant surgery that may result in revision surgery or explantation. Although there have been previous case reports of such extrusions through the tympanic membrane, this is the first well-documented report of an extrusion through the posterior canal wall which was previously intact. Clinical presentation: In this case report, we present a case of electrode array extruding through an initially intact posterior canal wall presenting as a delayed post-operative complication in a 13-year old Asian boy. Intervention: With reference to existing relevant literature, the case is discussed focusing on its management, possible contributing factors, and prevention strategies. Conclusion: Excessive thinning of the bony wall should be avoided as it can potentially break down. Abutment on the posterior canal wall by a coiled electrode array in the mastoid cavity exerting undue pressure on the bony wall can further contribute to additional stress. The implant surgeon must be cognizant of mastoid growth patterns in children. Life-long regular follow-up in implanted patients is crucial.
- Is Part Of:
- Cochlear implants international. Volume 16:Number 6(2015)
- Journal:
- Cochlear implants international
- Issue:
- Volume 16:Number 6(2015)
- Issue Display:
- Volume 16, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 6
- Issue Sort Value:
- 2015-0016-0006-0000
- Page Start:
- 341
- Page End:
- 344
- Publication Date:
- 2015-11
- Subjects:
- Cochlear implant -- Electrode array extrusion -- Post-operative complication -- Mastoid growth patterns
Cochlear implants -- Periodicals
617.882 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1556-9152 ↗
http://www.ingenta.com/journals/browse/whurr/cii ↗
http://www.ingentaconnect.com/content/maney/cii ↗
http://www.tandfonline.com/loi/ycii20 ↗
http://maneypublishing.com/ ↗ - DOI:
- 10.1179/1754762815Y.0000000006 ↗
- Languages:
- English
- ISSNs:
- 1467-0100
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3292.724200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 403.xml