A novel switched frequency 3He/1H high‐pass birdcage coil for imaging at 1.5 tesla. Issue 4 (6th October 2015)
- Record Type:
- Journal Article
- Title:
- A novel switched frequency 3He/1H high‐pass birdcage coil for imaging at 1.5 tesla. Issue 4 (6th October 2015)
- Main Title:
- A novel switched frequency 3He/1H high‐pass birdcage coil for imaging at 1.5 tesla
- Authors:
- Pratt, Ronald
Giaquinto, Randy
Ireland, Christopher
Daniels, Barret
Loew, Wolfgang
Higano, Nara
Cao, Xuefeng
Thomen, Robert
Woods, Jason
Dumoulin, Charles L. - Abstract:
- ABSTRACT: The ability to produce hyperpolarized noble gases 3 He and 129 Xe has opened up exciting possibilities for pulmonary magnetic resonance imaging (MRI). We have recently built a hyperpolarizer with the goal of using hyperpolarized 3 He gas for MRI in neonatal lungs in a dedicated small foot‐print 1.5 T MR scanner developed at our institution and sited in our Neonatal Intensive Care Unit. Although hyperpolarized gas imaging can provide unique insights into lung ventilation, acinar microstructure, and gas‐exchange dynamics, there is an undiminished need for 1 H MRI of the lung to provide anatomic references, B 1 and B0 maps, and 1 H images of lung parenchyma. To address this need, we designed, built and tested a novel radiofrequency body coil that provides a high‐pass birdcage coil that can be used for both 3 He and 1 H frequencies (48.65 and 63.86 MHz, respectively, at 1.5 T). To switch between frequencies, the birdcage coil has a large mechanical actuator that simultaneously changes the capacitance between every rung of the birdcage. Advantages of this coil design include: 1) quadrature excitation and reception at the 3 He and 1 H frequencies, 2) identical B 1 field maps for 3 He and 1 H imaging, 3) excellent signal‐to‐noise ratio and B 1 homogeneity at both frequencies, and 4) rapid (10–20 s) switching times between 3 He and 1 H operation. This report provides details of the coil's design and fabrication. Images of hyperpolarized 3 He and 1 H in phantoms and ex vivoABSTRACT: The ability to produce hyperpolarized noble gases 3 He and 129 Xe has opened up exciting possibilities for pulmonary magnetic resonance imaging (MRI). We have recently built a hyperpolarizer with the goal of using hyperpolarized 3 He gas for MRI in neonatal lungs in a dedicated small foot‐print 1.5 T MR scanner developed at our institution and sited in our Neonatal Intensive Care Unit. Although hyperpolarized gas imaging can provide unique insights into lung ventilation, acinar microstructure, and gas‐exchange dynamics, there is an undiminished need for 1 H MRI of the lung to provide anatomic references, B 1 and B0 maps, and 1 H images of lung parenchyma. To address this need, we designed, built and tested a novel radiofrequency body coil that provides a high‐pass birdcage coil that can be used for both 3 He and 1 H frequencies (48.65 and 63.86 MHz, respectively, at 1.5 T). To switch between frequencies, the birdcage coil has a large mechanical actuator that simultaneously changes the capacitance between every rung of the birdcage. Advantages of this coil design include: 1) quadrature excitation and reception at the 3 He and 1 H frequencies, 2) identical B 1 field maps for 3 He and 1 H imaging, 3) excellent signal‐to‐noise ratio and B 1 homogeneity at both frequencies, and 4) rapid (10–20 s) switching times between 3 He and 1 H operation. This report provides details of the coil's design and fabrication. Images of hyperpolarized 3 He and 1 H in phantoms and ex vivo rabbit lungs demonstrate the image quality obtained with the coil. © 2015 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 45B: 174–182, 2015 … (more)
- Is Part Of:
- Concepts in magnetic resonance. Volume 45:Issue 4(2015:Nov.)
- Journal:
- Concepts in magnetic resonance
- Issue:
- Volume 45:Issue 4(2015:Nov.)
- Issue Display:
- Volume 45, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 45
- Issue:
- 4
- Issue Sort Value:
- 2015-0045-0004-0000
- Page Start:
- 174
- Page End:
- 182
- Publication Date:
- 2015-10-06
- Subjects:
- switched frequency MRI coil -- birdcage coil -- hyperpolarized 3He imaging -- NICU MRI
Magnetic resonance -- Periodicals
Nuclear magnetic resonance -- Periodicals
Biomedical engineering -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
538.36 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-504X ↗
https://www.hindawi.com/journals/cmrb/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cmr.b.21309 ↗
- Languages:
- English
- ISSNs:
- 1552-5031
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3399.413430
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1499.xml