Automated insulin pump suspension for hypoglycaemia mitigation: development, implementation and implications. Issue 12 (5th October 2015)
- Record Type:
- Journal Article
- Title:
- Automated insulin pump suspension for hypoglycaemia mitigation: development, implementation and implications. Issue 12 (5th October 2015)
- Main Title:
- Automated insulin pump suspension for hypoglycaemia mitigation: development, implementation and implications
- Authors:
- Davis, T.
Salahi, A.
Welsh, J. B.
Bailey, T. S. - Abstract:
- Abstract : In type 1 diabetes (T1D), insulin replacement therapy should ideally replicate endogenous insulin secretion, but achieving this goal requires frequent adjustments to insulin delivery based on glucose levels and trends, carbohydrate intake and physical activity. An overriding concern for people taking insulin is hypoglycaemia, which remains the most feared consequence of insulin therapy and limits therapy intensification options. Although fully automated systems that achieve consistent euglycaemia in T1D remain an elusive goal, improvements in continuous glucose monitoring (CGM) sensors and control algorithms have enabled semi‐automated systems that lower the risk of hypoglycaemia, especially nocturnal hypoglycaemia. The present review focuses on an important advance in insulin delivery systems: the use of CGM data to stop insulin delivery in the presence of hypoglycaemia. Although conceptually simple, this strategy represents a critical step in the journey toward a fully closed‐loop artificial pancreas; the next steps in this journey are also discussed.
- Is Part Of:
- Diabetes, obesity & metabolism. Volume 17:Issue 12(2015:Dec.)
- Journal:
- Diabetes, obesity & metabolism
- Issue:
- Volume 17:Issue 12(2015:Dec.)
- Issue Display:
- Volume 17, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 17
- Issue:
- 12
- Issue Sort Value:
- 2015-0017-0012-0000
- Page Start:
- 1126
- Page End:
- 1132
- Publication Date:
- 2015-10-05
- Subjects:
- database research -- glucose monitoring -- glycaemic control -- insulin delivery -- insulin pump therapy -- type 1 diabetes -- hypoglycaemia -- artificial pancreas -- closed loop insulin therapy
Diabetes -- Periodicals
Obesity -- Periodicals
Metabolism -- Disorders -- Periodicals
Clinical pharmacology -- Periodicals
616.462 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1462-8902&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1463-1326 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/dom.12542 ↗
- Languages:
- English
- ISSNs:
- 1462-8902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3579.601970
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 71.xml