Cytotoxicity associated with electrospun polyvinyl alcohol. Issue 8 (9th January 2015)
- Record Type:
- Journal Article
- Title:
- Cytotoxicity associated with electrospun polyvinyl alcohol. Issue 8 (9th January 2015)
- Main Title:
- Cytotoxicity associated with electrospun polyvinyl alcohol
- Authors:
- Pathan, Saif G.
Fitzgerald, Lisa M.
Ali, Syed M.
Damrauer, Scott M.
Bide, Martin J.
Nelson, David W.
Ferran, Christiane
Phaneuf, Tina M.
Phaneuf, Matthew D. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Polyvinyl alcohol (PVA) is a synthetic, water‐soluble polymer, with applications in industries ranging from textiles to biomedical devices. Research on electrospinning of PVA has been targeted toward optimizing or finding novel applications in the biomedical field. However, the effects of electrospinning on PVA biocompatibility have not been thoroughly evaluated. In this study, the cytotoxicity of electrospun PVA (nPVA) which was not crosslinked after electrospinning was assessed. PVA polymers of several molecular weights were dissolved in distilled water and electrospun using the same parameters. Electrospun PVA materials with varying molecular weights were then dissolved in tissue culture medium and directly compared against solutions of nonelectrospun PVA polymer in human coronary artery smooth muscle cells and human coronary artery endothelial cells cultures. All nPVA solutions were cytotoxic at a threshold molar concentration that correlated with the molecular weight of the starting PVA polymer. In contrast, none of the nonelectrospun PVA solutions caused any cytotoxicity, regardless of their concentration in the cell culture. Evaluation of the nPVA material by differential scanning calorimetry confirmed that polymer degradation had occurred after electrospinning. To elucidate the identity of the nPVA component that caused cytotoxicity, nPVA materials were dissolved, fractionated using size exclusion columns,<abstract abstract-type="main"> <title>Abstract</title> <p>Polyvinyl alcohol (PVA) is a synthetic, water‐soluble polymer, with applications in industries ranging from textiles to biomedical devices. Research on electrospinning of PVA has been targeted toward optimizing or finding novel applications in the biomedical field. However, the effects of electrospinning on PVA biocompatibility have not been thoroughly evaluated. In this study, the cytotoxicity of electrospun PVA (nPVA) which was not crosslinked after electrospinning was assessed. PVA polymers of several molecular weights were dissolved in distilled water and electrospun using the same parameters. Electrospun PVA materials with varying molecular weights were then dissolved in tissue culture medium and directly compared against solutions of nonelectrospun PVA polymer in human coronary artery smooth muscle cells and human coronary artery endothelial cells cultures. All nPVA solutions were cytotoxic at a threshold molar concentration that correlated with the molecular weight of the starting PVA polymer. In contrast, none of the nonelectrospun PVA solutions caused any cytotoxicity, regardless of their concentration in the cell culture. Evaluation of the nPVA material by differential scanning calorimetry confirmed that polymer degradation had occurred after electrospinning. To elucidate the identity of the nPVA component that caused cytotoxicity, nPVA materials were dissolved, fractionated using size exclusion columns, and the different fractions were added to HCASMC and human coronary artery endothelial cells cultures. These studies indicated that the cytotoxic component of the different nPVA solutions were present in the low‐molecular‐weight fraction. Additionally, the amount of PVA present in the 3–10 kg/mol fraction was approximately sixfold greater than that in the nonelectrospun samples. In conclusion, electrospinning of PVA resulted in small‐molecular‐weight fractions that were cytotoxic to cells. This result demonstrates that biocompatibility of electrospun biodegradable polymers should not be assumed on the basis of success of their nonelectrospun predecessors. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B: 1652–1662, 2015.</p> </abstract> … (more)
- Is Part Of:
- Journal of biomedical materials research. Volume 103:Issue 8(2015:Nov.)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 103:Issue 8(2015:Nov.)
- Issue Display:
- Volume 103, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 103
- Issue:
- 8
- Issue Sort Value:
- 2015-0103-0008-0000
- Page Start:
- 1652
- Page End:
- 1662
- Publication Date:
- 2015-01-09
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jbm.b.33337 ↗
- Languages:
- English
- ISSNs:
- 1552-4973
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.725000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3293.xml