A new non‐invasive method of infant spirometry demonstrates a level of repeatability that is comparable to traditional methods. (November 2015)
- Record Type:
- Journal Article
- Title:
- A new non‐invasive method of infant spirometry demonstrates a level of repeatability that is comparable to traditional methods. (November 2015)
- Main Title:
- A new non‐invasive method of infant spirometry demonstrates a level of repeatability that is comparable to traditional methods
- Authors:
- Bentsen, Mariann H. L.
Haaland, Øystein A.
Lønning, Lise B.
Gudmundsdottir, Hrefna K.
Markestad, Trond
Halvorsen, Thomas - Abstract:
- <abstract abstract-type="main" id="apa13155-abs-0001"> <title>Abstract</title> <sec id="apa13155-sec-0001" sec-type="section"> <title>Aim</title> <p>The FloRight system provides novel non‐invasive infant spirometry based on electromagnetic inductance plethysmography. We investigated the consistency of repeated measurements carried out in a Norwegian neonatal intensive care unit (NICU) using the system and how well these were tolerated.</p> </sec> <sec id="apa13155-sec-0002" sec-type="section"> <title>Methods</title> <p>Tidal flow‐volume loops were obtained from 10 preterm infants at discharge, 10 stable growing preterm infants weighing about 1500 g and 10 term‐born infants. A nurse experienced with the system measured all patients before and after meals, and these measurements were repeated by nurses new to the system.</p> </sec> <sec id="apa13155-sec-0003" sec-type="section"> <title>Results</title> <p>The measurements were well tolerated by the infants. The repeatability for the two parameters 'tidal volume' (Vt) and 'time to peak tidal expiratory flow to total expiratory time' (Tptef/Te) were relatively poor, similar to previous methods. However, the repeatability was good for the new 'flow‐volume gravity mid‐point' (FVg) parameter. Repeatability was better for term than preterm infants, when measurements were obtained by the experienced nurse and for measurements carried out before meals.</p> </sec> <sec id="apa13155-sec-0004" sec-type="section"> <title>Conclusion</title><abstract abstract-type="main" id="apa13155-abs-0001"> <title>Abstract</title> <sec id="apa13155-sec-0001" sec-type="section"> <title>Aim</title> <p>The FloRight system provides novel non‐invasive infant spirometry based on electromagnetic inductance plethysmography. We investigated the consistency of repeated measurements carried out in a Norwegian neonatal intensive care unit (NICU) using the system and how well these were tolerated.</p> </sec> <sec id="apa13155-sec-0002" sec-type="section"> <title>Methods</title> <p>Tidal flow‐volume loops were obtained from 10 preterm infants at discharge, 10 stable growing preterm infants weighing about 1500 g and 10 term‐born infants. A nurse experienced with the system measured all patients before and after meals, and these measurements were repeated by nurses new to the system.</p> </sec> <sec id="apa13155-sec-0003" sec-type="section"> <title>Results</title> <p>The measurements were well tolerated by the infants. The repeatability for the two parameters 'tidal volume' (Vt) and 'time to peak tidal expiratory flow to total expiratory time' (Tptef/Te) were relatively poor, similar to previous methods. However, the repeatability was good for the new 'flow‐volume gravity mid‐point' (FVg) parameter. Repeatability was better for term than preterm infants, when measurements were obtained by the experienced nurse and for measurements carried out before meals.</p> </sec> <sec id="apa13155-sec-0004" sec-type="section"> <title>Conclusion</title> <p>The FloRight system proved feasible in a NICU setting. The repeatability of the lung function measurements was similar to those reported for traditional infant spirometry. The nurse's experience and the relationship to meals appeared to be important.</p> </sec> </abstract> … (more)
- Is Part Of:
- Acta pædiatrica. Volume 104:Number 11(2015:Nov.)
- Journal:
- Acta pædiatrica
- Issue:
- Volume 104:Number 11(2015:Nov.)
- Issue Display:
- Volume 104, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 104
- Issue:
- 11
- Issue Sort Value:
- 2015-0104-0011-0000
- Page Start:
- 1130
- Page End:
- 1137
- Publication Date:
- 2015-11
- Subjects:
- Pediatrics -- Periodicals
Pediatrics
618.92 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1651-2227 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/apa.13155 ↗
- Languages:
- English
- ISSNs:
- 0803-5253
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0642.400000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3692.xml