Quantification of liver fat with respiratory‐gated quantitative chemical shift encoded MRI. Issue 5 (1st April 2015)
- Record Type:
- Journal Article
- Title:
- Quantification of liver fat with respiratory‐gated quantitative chemical shift encoded MRI. Issue 5 (1st April 2015)
- Main Title:
- Quantification of liver fat with respiratory‐gated quantitative chemical shift encoded MRI
- Authors:
- Motosugi, Utaroh
Hernando, Diego
Bannas, Peter
Holmes, James H.
Wang, Kang
Shimakawa, Ann
Iwadate, Yuji
Taviani, Valentina
Rehm, Jennifer L.
Reeder, Scott B. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24896-sec-0001" sec-type="section"> <title>Purpose</title> <p>To evaluate free‐breathing chemical shift‐encoded (CSE) magnetic resonance imaging (MRI) for quantification of hepatic proton density fat‐fraction (PDFF). A secondary purpose was to evaluate hepatic R2* values measured using free‐breathing quantitative CSE‐MRI.</p> </sec> <sec id="jmri24896-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Fifty patients (mean age, 56 years) were prospectively recruited and underwent the following four acquisitions to measure PDFF and R2*; 1) conventional breath‐hold CSE‐MRI (BH‐CSE); 2) respiratory‐gated CSE‐MRI using respiratory bellows (BL‐CSE); 3) respiratory‐gated CSE‐MRI using navigator echoes (NV‐CSE); and 4) single voxel MR spectroscopy (MRS) as the reference standard for PDFF. Image quality was evaluated by two radiologists. MRI‐PDFF measured from the three CSE‐MRI methods were compared with MRS‐PDFF using linear regression. The PDFF and R2* values were compared using two one‐sided <italic>t</italic>‐test to evaluate statistical equivalence.</p> </sec> <sec id="jmri24896-sec-0003" sec-type="section"> <title>Results</title> <p>There was no significant difference in the image quality scores among the three CSE‐MRI methods for either PDFF (<italic>P</italic> = 1.000) or R2* maps (<italic>P</italic> = 0.359–1.000). Correlation coefficients (95% confidence<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24896-sec-0001" sec-type="section"> <title>Purpose</title> <p>To evaluate free‐breathing chemical shift‐encoded (CSE) magnetic resonance imaging (MRI) for quantification of hepatic proton density fat‐fraction (PDFF). A secondary purpose was to evaluate hepatic R2* values measured using free‐breathing quantitative CSE‐MRI.</p> </sec> <sec id="jmri24896-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Fifty patients (mean age, 56 years) were prospectively recruited and underwent the following four acquisitions to measure PDFF and R2*; 1) conventional breath‐hold CSE‐MRI (BH‐CSE); 2) respiratory‐gated CSE‐MRI using respiratory bellows (BL‐CSE); 3) respiratory‐gated CSE‐MRI using navigator echoes (NV‐CSE); and 4) single voxel MR spectroscopy (MRS) as the reference standard for PDFF. Image quality was evaluated by two radiologists. MRI‐PDFF measured from the three CSE‐MRI methods were compared with MRS‐PDFF using linear regression. The PDFF and R2* values were compared using two one‐sided <italic>t</italic>‐test to evaluate statistical equivalence.</p> </sec> <sec id="jmri24896-sec-0003" sec-type="section"> <title>Results</title> <p>There was no significant difference in the image quality scores among the three CSE‐MRI methods for either PDFF (<italic>P</italic> = 1.000) or R2* maps (<italic>P</italic> = 0.359–1.000). Correlation coefficients (95% confidence interval [CI]) for the PDFF comparisons were 0.98 (0.96–0.99) for BH‐, 0.99 (0.97–0.99) for BL‐, and 0.99 (0.98–0.99) for NV‐CSE. The statistical equivalence test revealed that the mean difference in PDFF and R2* between any two of the three CSE‐MRI methods was less than ±1 percentage point (pp) and ±5 s<sup>−1</sup>, respectively (<italic>P</italic> &lt; 0.046).</p> </sec> <sec id="jmri24896-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Respiratory‐gated CSE‐MRI with respiratory bellows or navigator echo are feasible methods to quantify liver PDFF and R2* and are as valid as the standard breath‐hold technique. J. Magn. Reson. Imaging 2015;42:1241–1248.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 42:Issue 5(2015)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 42:Issue 5(2015)
- Issue Display:
- Volume 42, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 5
- Issue Sort Value:
- 2015-0042-0005-0000
- Page Start:
- 1241
- Page End:
- 1248
- Publication Date:
- 2015-04-01
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24896 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3138.xml