Post‐operative monitoring of free muscle transfers by Laser Doppler Imaging: A prospective study. Issue 7 (10th August 2015)
- Record Type:
- Journal Article
- Title:
- Post‐operative monitoring of free muscle transfers by Laser Doppler Imaging: A prospective study. Issue 7 (10th August 2015)
- Main Title:
- Post‐operative monitoring of free muscle transfers by Laser Doppler Imaging: A prospective study
- Authors:
- Tschumi, Christian
Seyed Jafari, S. Morteza
Rothenberger, Jens
Van de Ville, Dimitri
Keel, Marius
Krause, Fabian
Shafighi, Maziar - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="micr22469-sec-0001" sec-type="section"> <title>Purpose</title> <p>Despite different existing methods, monitoring of free muscle transfer is still challenging. In the current study we evaluated our clinical setting regarding monitoring of such tissues, using a recent microcirculation‐imaging camera (EasyLDI) as an additional tool for detection of perfusion incompetency.</p> </sec> <sec id="micr22469-sec-0002" sec-type="section"> <title>Patients and methods</title> <p>This study was performed on seven patients with soft tissue defect, who underwent reconstruction with free gracilis muscle. Beside standard monitoring protocol (clinical assessment, temperature strips, and surface Doppler), hourly EasyLDI monitoring was performed for 48 hours. Thereby a baseline value (raised flap but connected to its vascular bundle) and an ischaemia perfusion value (completely resected flap) were measured at the same point.</p> </sec> <sec id="micr22469-sec-0003" sec-type="section"> <title>Results</title> <p>The mean age of the patients, mean baseline value, ischaemia value perfusion were 48.00 ± 13.42 years, 49.31 ± 17.33 arbitrary perfusion units (APU), 9.87 ± 4.22 APU, respectively. The LDI measured values in six free muscle transfers were compatible with hourly standard monitoring protocol, and normalized LDI values significantly increased during time (<italic>P</italic> &lt; 0.001,<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="micr22469-sec-0001" sec-type="section"> <title>Purpose</title> <p>Despite different existing methods, monitoring of free muscle transfer is still challenging. In the current study we evaluated our clinical setting regarding monitoring of such tissues, using a recent microcirculation‐imaging camera (EasyLDI) as an additional tool for detection of perfusion incompetency.</p> </sec> <sec id="micr22469-sec-0002" sec-type="section"> <title>Patients and methods</title> <p>This study was performed on seven patients with soft tissue defect, who underwent reconstruction with free gracilis muscle. Beside standard monitoring protocol (clinical assessment, temperature strips, and surface Doppler), hourly EasyLDI monitoring was performed for 48 hours. Thereby a baseline value (raised flap but connected to its vascular bundle) and an ischaemia perfusion value (completely resected flap) were measured at the same point.</p> </sec> <sec id="micr22469-sec-0003" sec-type="section"> <title>Results</title> <p>The mean age of the patients, mean baseline value, ischaemia value perfusion were 48.00 ± 13.42 years, 49.31 ± 17.33 arbitrary perfusion units (APU), 9.87 ± 4.22 APU, respectively. The LDI measured values in six free muscle transfers were compatible with hourly standard monitoring protocol, and normalized LDI values significantly increased during time (<italic>P</italic> &lt; 0.001, <italic>r</italic> = 0.412). One of the flaps required a return to theatre 17 hours after the operation, where an unsalvageable flap loss was detected. All normalized LDI values of this flap were under the ischaemia perfusion level and the trend was significantly descending during time (<italic>P</italic> &lt; 0.001, <italic>r</italic> = −0.870).</p> </sec> <sec id="micr22469-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Due to the capability of early detection of perfusion incompetency, LDI may be recommended as an additional post‐operative monitoring device for free muscle flaps, for early detection of suspected failing flaps and for validation of other methods. © 2015 Wiley Periodicals, Inc. Microsurgery 35:528–535, 2015.</p> </sec> </abstract> … (more)
- Is Part Of:
- Microsurgery. Volume 35:Issue 7(2015)
- Journal:
- Microsurgery
- Issue:
- Volume 35:Issue 7(2015)
- Issue Display:
- Volume 35, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 35
- Issue:
- 7
- Issue Sort Value:
- 2015-0035-0007-0000
- Page Start:
- 528
- Page End:
- 535
- Publication Date:
- 2015-08-10
- Subjects:
- Microsurgery -- Periodicals
617.05 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-2752 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/micr.22469 ↗
- Languages:
- English
- ISSNs:
- 0738-1085
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5760.770000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3644.xml