Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion. Issue 13 (15th October 2015)
- Record Type:
- Journal Article
- Title:
- Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion. Issue 13 (15th October 2015)
- Main Title:
- Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion
- Authors:
- Abbasi, Mostafa
Azadani, Ali N. - Abstract:
- <abstract abstract-type="author" id="ab0010"> <title id="sect0005">Abstract</title> <sec> <p id="sp0060">Transcatheter aortic valve replacement (TAVR) is an established treatment alternative to surgical valve replacement in high-risk patients with severe symptomatic aortic stenosis. The current guidelines for TAVR are to upsize transcatheter aortic valve (TAV) relative to the native annulus to secure the device and minimize paravalvular leakage. Unlike surgical stented bioprosthetic valves where leaflets are attached to a rigid frame, TAVs must expand to fit within the native annulus. Fully-expanded circular TAVs have consistent leaflet kinematics; however, subtle variations in the degree of stent expansion may affect leaflet coaptation. The objective of this study was to determine the impact of incomplete TAV expansion on leaflet stress and strain distributions. In this study, we developed finite element models of a 23 mm homemade TAV expanded to diameters ranging from 18 to 23 mm in 1 mm increments. Through dynamic finite element simulations, we found that leaflet stress and strain distributions were dependent on the diameter of the inflated TAV. After complete expansion of the TAV to 23 mm, high stress and strain regions were observed primarily in the commissures during diastole. However, 2–3 mm incomplete TAV stent expansion induced localized high stress regions within the TAV commissures, while 4–5 mm incomplete stent expansion induced localized high stress regions<abstract abstract-type="author" id="ab0010"> <title id="sect0005">Abstract</title> <sec> <p id="sp0060">Transcatheter aortic valve replacement (TAVR) is an established treatment alternative to surgical valve replacement in high-risk patients with severe symptomatic aortic stenosis. The current guidelines for TAVR are to upsize transcatheter aortic valve (TAV) relative to the native annulus to secure the device and minimize paravalvular leakage. Unlike surgical stented bioprosthetic valves where leaflets are attached to a rigid frame, TAVs must expand to fit within the native annulus. Fully-expanded circular TAVs have consistent leaflet kinematics; however, subtle variations in the degree of stent expansion may affect leaflet coaptation. The objective of this study was to determine the impact of incomplete TAV expansion on leaflet stress and strain distributions. In this study, we developed finite element models of a 23 mm homemade TAV expanded to diameters ranging from 18 to 23 mm in 1 mm increments. Through dynamic finite element simulations, we found that leaflet stress and strain distributions were dependent on the diameter of the inflated TAV. After complete expansion of the TAV to 23 mm, high stress and strain regions were observed primarily in the commissures during diastole. However, 2–3 mm incomplete TAV stent expansion induced localized high stress regions within the TAV commissures, while 4–5 mm incomplete stent expansion induced localized high stress regions within the belly of the TAV leaflets during the diastolic phase of the cardiac cycle. Increased mechanical stress and flexural deformation on TAV leaflets due to incomplete stent expansion may lead to accelerated tissue degeneration and diminished long-term valve durability.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of biomechanics. Volume 48:Issue 13(2015)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 48:Issue 13(2015)
- Issue Display:
- Volume 48, Issue 13 (2015)
- Year:
- 2015
- Volume:
- 48
- Issue:
- 13
- Issue Sort Value:
- 2015-0048-0013-0000
- Page Start:
- 3672
- Page End:
- 3680
- Publication Date:
- 2015-10-15
- Subjects:
- Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2015.08.012 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3400.xml