Fatal false‐negative transfusion infection involving a buffy coat platelet pool contaminated with biofilm‐positive Staphylococcus epidermidis: a case report. Issue 10 (18th May 2015)
- Record Type:
- Journal Article
- Title:
- Fatal false‐negative transfusion infection involving a buffy coat platelet pool contaminated with biofilm‐positive Staphylococcus epidermidis: a case report. Issue 10 (18th May 2015)
- Main Title:
- Fatal false‐negative transfusion infection involving a buffy coat platelet pool contaminated with biofilm‐positive Staphylococcus epidermidis: a case report
- Authors:
- Kou, Yuntong
Pagotto, Franco
Hannach, Barbara
Ramirez‐Arcos, Sandra - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf13154-sec-0001" sec-type="section"> <title>BACKGROUND</title> <p>Bacterial contamination of platelet concentrates (PCs) poses the major posttransfusion infectious risk in developed countries. The aerobic microorganism most frequently isolated from PCs is coagulase‐negative <italic>Staphylococcus epidermidis</italic>, a normal inhabitant of the human skin, which has been involved in fatal transfusion reactions worldwide.</p> </sec> <sec id="trf13154-sec-0002" sec-type="section"> <title>CASE REPORT</title> <p>In September 2014, a splenectomized elderly male patient, suffering from leukemia, was transfused with two 5‐day‐old buffy coat platelet (PLT) pools. The patient returned to emergency on the same day with a low‐grade fever. He was bacteremic and died on the next day. Microbiology and molecular testing of a blood sample from the patient and one of the PCs yielded the same <italic>S. epidermidis</italic> strain. Further analysis demonstrated that this <italic>S. epidermidis</italic> isolate displays a biofilm‐positive phenotype in PCs.</p> </sec> <sec id="trf13154-sec-0003" sec-type="section"> <title>DISCUSSION</title> <p>At Canadian Blood Services, PCs are screened for bacterial contamination with the BacT/ALERT system (bioMérieux) at approximately 24 hours postcollection. The implicated PC had been tested and yielded a false‐negative culture result. A titration experiment<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf13154-sec-0001" sec-type="section"> <title>BACKGROUND</title> <p>Bacterial contamination of platelet concentrates (PCs) poses the major posttransfusion infectious risk in developed countries. The aerobic microorganism most frequently isolated from PCs is coagulase‐negative <italic>Staphylococcus epidermidis</italic>, a normal inhabitant of the human skin, which has been involved in fatal transfusion reactions worldwide.</p> </sec> <sec id="trf13154-sec-0002" sec-type="section"> <title>CASE REPORT</title> <p>In September 2014, a splenectomized elderly male patient, suffering from leukemia, was transfused with two 5‐day‐old buffy coat platelet (PLT) pools. The patient returned to emergency on the same day with a low‐grade fever. He was bacteremic and died on the next day. Microbiology and molecular testing of a blood sample from the patient and one of the PCs yielded the same <italic>S. epidermidis</italic> strain. Further analysis demonstrated that this <italic>S. epidermidis</italic> isolate displays a biofilm‐positive phenotype in PCs.</p> </sec> <sec id="trf13154-sec-0003" sec-type="section"> <title>DISCUSSION</title> <p>At Canadian Blood Services, PCs are screened for bacterial contamination with the BacT/ALERT system (bioMérieux) at approximately 24 hours postcollection. The implicated PC had been tested and yielded a false‐negative culture result. A titration experiment indicated that, at the time of screening, the contaminated PC had a titer of less than 0.74 colony‐forming units (CFU)/mL (&lt;227 CFUs/unit) of <italic>S. epidermidis</italic>. Mathematical models have predicted that up to 70% of PCs contaminated with coagulase‐negative staphylococci at concentrations of 0.02 CFU/mL can be missed by BacT/ALERT screening.</p> </sec> <sec id="trf13154-sec-0004" sec-type="section"> <title>CONCLUSION</title> <p>Despite several mitigation strategies, false‐negative cultures with current PLT screening practices still occur. This report creates awareness of the pathogenicity of opportunistic <italic>S. epidermidis</italic>, a low‐virulence organism, in susceptible patients who may not develop a typical transfusion reaction.</p> </sec> </abstract> … (more)
- Is Part Of:
- Transfusion. Volume 55:Issue 10(2015)
- Journal:
- Transfusion
- Issue:
- Volume 55:Issue 10(2015)
- Issue Display:
- Volume 55, Issue 10 (2015)
- Year:
- 2015
- Volume:
- 55
- Issue:
- 10
- Issue Sort Value:
- 2015-0055-0010-0000
- Page Start:
- 2384
- Page End:
- 2389
- Publication Date:
- 2015-05-18
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.13154 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3925.xml