Effects of Hemodialysis on Tei Index: Comparison between Flow Doppler and Tissue Doppler Imaging. Issue 10 (14th January 2015)
- Record Type:
- Journal Article
- Title:
- Effects of Hemodialysis on Tei Index: Comparison between Flow Doppler and Tissue Doppler Imaging. Issue 10 (14th January 2015)
- Main Title:
- Effects of Hemodialysis on Tei Index: Comparison between Flow Doppler and Tissue Doppler Imaging
- Authors:
- Gerede, Demet Menekse
Turhan, Sibel
Kaya, Cansin Tulunay
Ozcan, Ozgur Ulas
Goksuluk, Huseyin
Vurgun, Veysel Kutay
Dincer, Irem
Kutlay, Sim
Erturk, Sehsuvar
Erol, Cetin - Abstract:
- <abstract abstract-type="main" id="echo12895-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12895-sec-0001" sec-type="section"> <title>Objective</title> <p>Myocardial performance index (MPI, Tei index) has been described as a noninvasive measurement of left ventricle (LV) function. Our aim was to investigate the influence of preload on the LV MPI obtained by pulsed‐wave tissue Doppler imaging (PWTDI) and determined by flow Doppler waveforms in patients with end‐stage chronic renal failure (CRF). The second aim of this study was to investigate the relationship between the Tei indices obtained by both methods.</p> </sec> <sec id="echo12895-sec-0002" sec-type="section"> <title>Methods</title> <p>Eighty‐four patients on regular hemodialysis (HD) treatment were included (mean age of 45.3 ± 14.5 years). Standard echocardiographic measurements, the Tei indices obtained by conventional flow Doppler and PWTDI methods, mitral inflow velocities, and mitral lateral annulus tissue Doppler velocities were measured immediately before and after hemodialysis.</p> </sec> <sec id="echo12895-sec-0003" sec-type="section"> <title>Results</title> <p>After HD, weight loss in patients was significantly revealed (predialysis 63.6 ± 13.3 kg; postdialysis 60.9 ± 13.0 kg; P &lt; 0.001). Left ventricle and left atrium diameters were significantly decreased after HD. Transmitral E and A velocities decreased after HD. Although Tei index measuring by conventional flow Doppler<abstract abstract-type="main" id="echo12895-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12895-sec-0001" sec-type="section"> <title>Objective</title> <p>Myocardial performance index (MPI, Tei index) has been described as a noninvasive measurement of left ventricle (LV) function. Our aim was to investigate the influence of preload on the LV MPI obtained by pulsed‐wave tissue Doppler imaging (PWTDI) and determined by flow Doppler waveforms in patients with end‐stage chronic renal failure (CRF). The second aim of this study was to investigate the relationship between the Tei indices obtained by both methods.</p> </sec> <sec id="echo12895-sec-0002" sec-type="section"> <title>Methods</title> <p>Eighty‐four patients on regular hemodialysis (HD) treatment were included (mean age of 45.3 ± 14.5 years). Standard echocardiographic measurements, the Tei indices obtained by conventional flow Doppler and PWTDI methods, mitral inflow velocities, and mitral lateral annulus tissue Doppler velocities were measured immediately before and after hemodialysis.</p> </sec> <sec id="echo12895-sec-0003" sec-type="section"> <title>Results</title> <p>After HD, weight loss in patients was significantly revealed (predialysis 63.6 ± 13.3 kg; postdialysis 60.9 ± 13.0 kg; P &lt; 0.001). Left ventricle and left atrium diameters were significantly decreased after HD. Transmitral E and A velocities decreased after HD. Although Tei index measuring by conventional flow Doppler method significantly increased, Tei index measuring by PWTDI did not change after HD.</p> </sec> <sec id="echo12895-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The conventional flow Doppler‐derived LV Tei index is influenced by hemodialysis. However, PWTDI‐derived LV Tei index is not influenced by hemodialysis. The loading status of a patient should be taken into account during the application of the Tei index to the evaluation of myocardial performance.</p> </sec> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 32:Issue 10(2015:Oct.)
- Journal:
- Echocardiography
- Issue:
- Volume 32:Issue 10(2015:Oct.)
- Issue Display:
- Volume 32, Issue 10 (2015)
- Year:
- 2015
- Volume:
- 32
- Issue:
- 10
- Issue Sort Value:
- 2015-0032-0010-0000
- Page Start:
- 1520
- Page End:
- 1526
- Publication Date:
- 2015-01-14
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12895 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4164.xml