A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system. Issue 6 (October 2015)
- Record Type:
- Journal Article
- Title:
- A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system. Issue 6 (October 2015)
- Main Title:
- A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system
- Authors:
- Enjeti, Anoop
Granter, Neil
Ashraf, Asma
Fletcher, Linda
Branford, Susan
Rowlings, Philip
Dooley, Susan - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Summary</title> <p>An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.</p> <p>The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (<italic>n</italic> = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.</p> <p>The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at &gt;0.1–⩽10 IS was 78.2% and at ⩽0.001 was 80%,<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Summary</title> <p>An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.</p> <p>The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (<italic>n</italic> = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.</p> <p>The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at &gt;0.1–⩽10 IS was 78.2% and at ⩽0.001 was 80%, compared to 86.8% in the &gt;0.01–⩽0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.</p> <p>Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.</p> </sec> </abstract> … (more)
- Is Part Of:
- Pathology. Volume 47:Issue 6(2015:Oct.)
- Journal:
- Pathology
- Issue:
- Volume 47:Issue 6(2015:Oct.)
- Issue Display:
- Volume 47, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 47
- Issue:
- 6
- Issue Sort Value:
- 2015-0047-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10
- Subjects:
- Pathology -- Periodicals
616.0705 - Journal URLs:
- http://informahealthcare.com/loi/pat ↗
http://journals.lww.com/pathologyrcpa/pages/issuelist.aspx ↗
http://pathologyjournal.rcpa.edu.au/ ↗
http://journals.lww.com ↗
http://www.tandf.co.uk/journals/titles/00313025.asp ↗ - DOI:
- 10.1097/PAT.0000000000000293 ↗
- Languages:
- English
- ISSNs:
- 0031-3025
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6412.810000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3223.xml