Comparison of the Freelite serum free light chain (SFLC) assay with serum and urine electrophoresis/immunofixation and the N Latex FLC assay. Issue 6 (October 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of the Freelite serum free light chain (SFLC) assay with serum and urine electrophoresis/immunofixation and the N Latex FLC assay. Issue 6 (October 2015)
- Main Title:
- Comparison of the Freelite serum free light chain (SFLC) assay with serum and urine electrophoresis/immunofixation and the N Latex FLC assay
- Authors:
- Sasson, S. C.
McGill, K.
Wienholt, L.
Carr, A.
Brown, D. A.
Kelleher, A. D.
Breit, S. N.
Sewell, W. A. - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Summary</title> <p>Few reports have compared available serum free light chain (SFLC) assays. Here, a retrospective audit of the Freelite SFLC assay compared results to electrophoresis (EP)/immunofixation (IFX) and the N Latex FLC assay.</p> <p>A total of 244 samples collected over 3.5 months were studied using the Freelite and N Latex FLC nephelometry assays. Results were compared with serum and/or urine EP/IFX. The precision and linearity of the N Latex FLC assay was examined.</p> <p>Detectable paraprotein by serum or urine EP/IFX was present in 94% of samples with kappa and 100% with lambda FLC restriction. The correlation between the assays was higher for kappa (rho = 0.97) than lambda (rho = 0.89) especially when lambda results were above the upper limit of normal (rho = 0.62). Agreement in the categorical diagnosis as measured by the Cohen's kappa statistic was good (0.70). The N Latex FLC assay displayed good precision and linearity. In discordant samples the Freelite and N Latex FLC assays had equivalent agreement with IFX.</p> <p>Traditional methods of EP/IFX detected paraproteins in the majority of cases. Correlation between the Freelite and N Latex FLC assay is better for kappa than lambda FLC. The two assays are not entirely equivalent. Care should be taken by interpreting physicians and laboratories considering switching assays.</p> </sec> </abstract>
- Is Part Of:
- Pathology. Volume 47:Issue 6(2015:Oct.)
- Journal:
- Pathology
- Issue:
- Volume 47:Issue 6(2015:Oct.)
- Issue Display:
- Volume 47, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 47
- Issue:
- 6
- Issue Sort Value:
- 2015-0047-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10
- Subjects:
- Pathology -- Periodicals
616.0705 - Journal URLs:
- http://informahealthcare.com/loi/pat ↗
http://journals.lww.com/pathologyrcpa/pages/issuelist.aspx ↗
http://pathologyjournal.rcpa.edu.au/ ↗
http://journals.lww.com ↗
http://www.tandf.co.uk/journals/titles/00313025.asp ↗ - DOI:
- 10.1097/PAT.0000000000000316 ↗
- Languages:
- English
- ISSNs:
- 0031-3025
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6412.810000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3222.xml