Assessment of the performance of small field of view gamma cameras for sentinel node imaging. Issue 11 (November 2015)
- Record Type:
- Journal Article
- Title:
- Assessment of the performance of small field of view gamma cameras for sentinel node imaging. Issue 11 (November 2015)
- Main Title:
- Assessment of the performance of small field of view gamma cameras for sentinel node imaging
- Authors:
- Ng, Aik Hao
Clay, David
Blackshaw, Patricia E.
Bugby, Sarah L.
Morgan, Paul S.
Lees, John E.
Perkins, Alan C. - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective</title> <p>To develop a method for the assessment of small field of view (SFOV) gamma cameras using a novel phantom designed to simulate the localization of sentinel nodes in the presence of a high-activity injection site.</p> </sec> <sec> <title>Materials and methods</title> <p>The phantom consisted of a cube-shaped acrylic glass support frame. Sixteen acrylic glass plates and nine bars were stacked within the frame to allow a variable configuration of the simulated node depth and node-to-injection site separation. Syringes filled with <sup>99m</sup>Tc were used to simulate activity at the injection site and node. Scintigraphic imaging was carried out and the images were assessed subjectively and quantitatively through calculation of the contrast-to-noise ratio. The detection performance of an SFOV gamma camera was then compared with that of a large field of view gamma camera.</p> </sec> <sec> <title>Results</title> <p>The detectability studies showed that the SFOV gamma camera could detect low activity in nodes by visual examination of images and with contrast-to-noise ratios ranging from 3 to 62. In particular, the phantom showed the limits of node detection using an SFOV gamma camera over activity ratios less than 1 : 100 and at depths below 45 mm with 25 mm of node-to-injection site separation. Visual subjective assessment of images acquired under the same conditions showed that the<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective</title> <p>To develop a method for the assessment of small field of view (SFOV) gamma cameras using a novel phantom designed to simulate the localization of sentinel nodes in the presence of a high-activity injection site.</p> </sec> <sec> <title>Materials and methods</title> <p>The phantom consisted of a cube-shaped acrylic glass support frame. Sixteen acrylic glass plates and nine bars were stacked within the frame to allow a variable configuration of the simulated node depth and node-to-injection site separation. Syringes filled with <sup>99m</sup>Tc were used to simulate activity at the injection site and node. Scintigraphic imaging was carried out and the images were assessed subjectively and quantitatively through calculation of the contrast-to-noise ratio. The detection performance of an SFOV gamma camera was then compared with that of a large field of view gamma camera.</p> </sec> <sec> <title>Results</title> <p>The detectability studies showed that the SFOV gamma camera could detect low activity in nodes by visual examination of images and with contrast-to-noise ratios ranging from 3 to 62. In particular, the phantom showed the limits of node detection using an SFOV gamma camera over activity ratios less than 1 : 100 and at depths below 45 mm with 25 mm of node-to-injection site separation. Visual subjective assessment of images acquired under the same conditions showed that the SFOV gamma camera was superior to a large field of view camera for the detection of nodes at a node-to-injection site separation of 25 mm.</p> </sec> <sec> <title>Conclusion</title> <p>A low-cost phantom has been designed and fabricated that provides a versatile method for the assessment of SFOV gamma cameras intended for sentinel node imaging.</p> </sec> </abstract> … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 36:Issue 11(2015:Nov.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 36:Issue 11(2015:Nov.)
- Issue Display:
- Volume 36, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 11
- Issue Sort Value:
- 2015-0036-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-11
- Subjects:
- Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000377 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2969.xml