Parallel enzyme‐linked immunosorbent assay screening for human immunodeficiency virus among blood donors in five Chinese blood centres: a retrospective analysis. Issue 4 (23rd June 2015)
- Record Type:
- Journal Article
- Title:
- Parallel enzyme‐linked immunosorbent assay screening for human immunodeficiency virus among blood donors in five Chinese blood centres: a retrospective analysis. Issue 4 (23rd June 2015)
- Main Title:
- Parallel enzyme‐linked immunosorbent assay screening for human immunodeficiency virus among blood donors in five Chinese blood centres: a retrospective analysis
- Authors:
- Zeng, P.
Liu, J.
Wang, J.
Dong, X.
Li, J.
Bi, X.
Ma, H.
Wen, X.
He, M.
Liu, Y.
Ness, P.
Shan, H.
for the International Component of the NHLBI Recipient Epidemiology and Donor Evaluation Study‐II (REDS‐II) - Abstract:
- <abstract abstract-type="main" id="tme12217-abs-0001"> <title>SUMMARY</title> <sec id="tme12217-sec-0001" sec-type="section"> <title>Aims</title> <p id="tme12217-para-0001">To evaluate the strategy of parallel screening with different enzyme‐linked immunosorbent assays (ELISA) among Chinese blood donors.</p> </sec> <sec id="tme12217-sec-0002" sec-type="section"> <title>Background</title> <p id="tme12217-para-0002">Parallel screening with ELISA has been the main strategy to detect human immunodeficiency virus (HIV) in blood donations in China for more than a decade. The performance of the strategy should be analysed.</p> </sec> <sec id="tme12217-sec-0003" sec-type="section"> <title>Methods</title> <p id="tme12217-para-0003">A total of 821, 927 donations collected from five Chinese blood centres in 2008–2010 were tested using two third‐generation ELISAs by different manufacturers licenced and confirmed by the Western blot (WB) in this study. The confirmatory positive predictive values (PPV), false positive rates (FPR), false negative rates (FNR) and potential risks for transfusion resulting from single or sequential ELISA screening were evaluated.</p> </sec> <sec id="tme12217-sec-0004" sec-type="section"> <title>Results</title> <p id="tme12217-para-0004">A total of 5318 (0·647%) of donations screened HIV reactive and were discarded. WB confirmatory results on 1668 available samples suggested that PPVs for dual ELISA, one round ELISA reactive and grey zone samples were 75·1,<abstract abstract-type="main" id="tme12217-abs-0001"> <title>SUMMARY</title> <sec id="tme12217-sec-0001" sec-type="section"> <title>Aims</title> <p id="tme12217-para-0001">To evaluate the strategy of parallel screening with different enzyme‐linked immunosorbent assays (ELISA) among Chinese blood donors.</p> </sec> <sec id="tme12217-sec-0002" sec-type="section"> <title>Background</title> <p id="tme12217-para-0002">Parallel screening with ELISA has been the main strategy to detect human immunodeficiency virus (HIV) in blood donations in China for more than a decade. The performance of the strategy should be analysed.</p> </sec> <sec id="tme12217-sec-0003" sec-type="section"> <title>Methods</title> <p id="tme12217-para-0003">A total of 821, 927 donations collected from five Chinese blood centres in 2008–2010 were tested using two third‐generation ELISAs by different manufacturers licenced and confirmed by the Western blot (WB) in this study. The confirmatory positive predictive values (PPV), false positive rates (FPR), false negative rates (FNR) and potential risks for transfusion resulting from single or sequential ELISA screening were evaluated.</p> </sec> <sec id="tme12217-sec-0004" sec-type="section"> <title>Results</title> <p id="tme12217-para-0004">A total of 5318 (0·647%) of donations screened HIV reactive and were discarded. WB confirmatory results on 1668 available samples suggested that PPVs for dual ELISA, one round ELISA reactive and grey zone samples were 75·1, 0·7 and 0·5%, respectively. Eight out of 1124 one round ELISA reactive and 1 out of 195 grey zone samples were WB confirmed positive. All but one ELISA assay displayed comparable PPVs but variable FPRs and FNRs that differed by blood centre.</p> </sec> <sec id="tme12217-sec-0005" sec-type="section"> <title>Conclusions</title> <p id="tme12217-para-0005">In the absence of nucleic acid testing (NAT), parallel ELISA screening prevented a substantial number of HIV infected donations from entering the Chinese blood supply. However, the loss of false positive donors should be re‐evaluated especially given the frequently reported blood supply shortage in China.</p> </sec> </abstract> … (more)
- Is Part Of:
- Transfusion medicine. Volume 25:Issue 4(2015)
- Journal:
- Transfusion medicine
- Issue:
- Volume 25:Issue 4(2015)
- Issue Display:
- Volume 25, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2015-0025-0004-0000
- Page Start:
- 259
- Page End:
- 264
- Publication Date:
- 2015-06-23
- Subjects:
- Blood -- Transfusion -- Periodicals
615.39 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=tme ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-3148 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/tme.12217 ↗
- Languages:
- English
- ISSNs:
- 0958-7578
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.706000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3767.xml