Comparison of iSED and Ves‐Matic Cube 200 Erythrocyte Sedimentation Rate Measurements With Westergren Method. Issue 5 (17th August 2014)
- Record Type:
- Journal Article
- Title:
- Comparison of iSED and Ves‐Matic Cube 200 Erythrocyte Sedimentation Rate Measurements With Westergren Method. Issue 5 (17th August 2014)
- Main Title:
- Comparison of iSED and Ves‐Matic Cube 200 Erythrocyte Sedimentation Rate Measurements With Westergren Method
- Authors:
- Boğdaycioğlu, Nihal
Yilmaz, Fatma Meric
Sezer, Sevilay
Oğuz, Esra - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21786-sec-0010" sec-type="section"> <title>Background</title> <p>The erythrocyte sedimentation rate (ESR) test is performed widely in laboratories. Besides the traditional Westergren method, new methods have been developed for ESR measurements. We aimed to compare the instruments using new methods, iSED (Alcor Scientific) and Ves‐Matic Cube 200 (Diesse Diagnostica Senese, Italy) with the Westergren method.</p> </sec> <sec id="jcla21786-sec-0020" sec-type="section"> <title>Methods</title> <p>Blood samples from 136 patients were taken into EDTA tubes for automated analyzers and citrated tubes for Westergren method. Patients were divided into three groups— low, medium, and high—according to their sedimentation rates. Precision, stability, and interference studies of the methods were performed.</p> </sec> <sec id="jcla21786-sec-0030" sec-type="section"> <title>Results</title> <p>The iSED sedimentation method (<italic>n</italic> = 136) yielded a slope of (0.61–0.84), with an intercept of (−2.32 to 1.89), which resulted in a mean bias of 13; and the Ves‐Matic Cube 200 method (<italic>n</italic> = 136) yielded a slope of (0.85–1.00), with an intercept of (0.00–3.07), which resulted in a mean bias of 1.4 in Passing–Bablok regression analysis compared to the reference method.</p> </sec> <sec id="jcla21786-sec-0040" sec-type="section"> <title>Conclusion</title> <p>iSED sedimentation<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21786-sec-0010" sec-type="section"> <title>Background</title> <p>The erythrocyte sedimentation rate (ESR) test is performed widely in laboratories. Besides the traditional Westergren method, new methods have been developed for ESR measurements. We aimed to compare the instruments using new methods, iSED (Alcor Scientific) and Ves‐Matic Cube 200 (Diesse Diagnostica Senese, Italy) with the Westergren method.</p> </sec> <sec id="jcla21786-sec-0020" sec-type="section"> <title>Methods</title> <p>Blood samples from 136 patients were taken into EDTA tubes for automated analyzers and citrated tubes for Westergren method. Patients were divided into three groups— low, medium, and high—according to their sedimentation rates. Precision, stability, and interference studies of the methods were performed.</p> </sec> <sec id="jcla21786-sec-0030" sec-type="section"> <title>Results</title> <p>The iSED sedimentation method (<italic>n</italic> = 136) yielded a slope of (0.61–0.84), with an intercept of (−2.32 to 1.89), which resulted in a mean bias of 13; and the Ves‐Matic Cube 200 method (<italic>n</italic> = 136) yielded a slope of (0.85–1.00), with an intercept of (0.00–3.07), which resulted in a mean bias of 1.4 in Passing–Bablok regression analysis compared to the reference method.</p> </sec> <sec id="jcla21786-sec-0040" sec-type="section"> <title>Conclusion</title> <p>iSED sedimentation showed a poor correlation and a high bias (&gt;10%) with the Westergren method, and Ves‐Matic Cube 200 method showed a higher correlation and a lower bias than the iSED device when compared with Westergren reference method. These instruments should be carefully monitored.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 29:Issue 5(2015)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 29:Issue 5(2015)
- Issue Display:
- Volume 29, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 5
- Issue Sort Value:
- 2015-0029-0005-0000
- Page Start:
- 397
- Page End:
- 404
- Publication Date:
- 2014-08-17
- Subjects:
- Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.21786 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4280.xml