Time-related bond strength of resin-reinforced glass ionomer cement under various light exposure conditions. Issue 3 (September 2015)
- Record Type:
- Journal Article
- Title:
- Time-related bond strength of resin-reinforced glass ionomer cement under various light exposure conditions. Issue 3 (September 2015)
- Main Title:
- Time-related bond strength of resin-reinforced glass ionomer cement under various light exposure conditions
- Authors:
- Fukino, Yoshitaka
Komori, Akira - Abstract:
- <abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Purpose</title> <p id="spar0005">This study's purpose was to determine the time-related bond strengths of light-cured resin-reinforced glass ionomer cement (LCGIC) under various conditions of light exposure.</p> </sec> <sec> <title id="sect0015">Materials and methods</title> <p id="spar0010">480 freshly extracted bovine mandibular incisors were randomly divided into 32 groups. The study was performed in 4 light curing conditions, at 4 bond-testing times, and by 2 bond testing methods. For dental curing lights, LED using a source consisting of high intensity light-emitting diode, TQH (tungsten quartz halogen lamp) and PAC (plasma arc lamp) were used. Light exposure from 2 directions was performed under 4 conditions: for 5 s with LED (LED-5s), for 10 s with LED (LED-10s), for 20 s with TQH, and for 3 s with PAC. Tensile and shear bond tests were performed at 4 time-points after light exposure, i.e. 0 min, 3 min, 30 min, and 24 h.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">LED had the highest peak output by 44.7 mW/cm<sup>2</sup> at 458 nm. Significant increase over time of tensile and shear bond strength was observed in all of the groups. TQH and PAC had low tensile bond strength just after the exposure. LED-10's demonstrated significantly higher tensile and shear bond strength compared with other groups.</p> </sec> <sec> <title<abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Purpose</title> <p id="spar0005">This study's purpose was to determine the time-related bond strengths of light-cured resin-reinforced glass ionomer cement (LCGIC) under various conditions of light exposure.</p> </sec> <sec> <title id="sect0015">Materials and methods</title> <p id="spar0010">480 freshly extracted bovine mandibular incisors were randomly divided into 32 groups. The study was performed in 4 light curing conditions, at 4 bond-testing times, and by 2 bond testing methods. For dental curing lights, LED using a source consisting of high intensity light-emitting diode, TQH (tungsten quartz halogen lamp) and PAC (plasma arc lamp) were used. Light exposure from 2 directions was performed under 4 conditions: for 5 s with LED (LED-5s), for 10 s with LED (LED-10s), for 20 s with TQH, and for 3 s with PAC. Tensile and shear bond tests were performed at 4 time-points after light exposure, i.e. 0 min, 3 min, 30 min, and 24 h.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">LED had the highest peak output by 44.7 mW/cm<sup>2</sup> at 458 nm. Significant increase over time of tensile and shear bond strength was observed in all of the groups. TQH and PAC had low tensile bond strength just after the exposure. LED-10's demonstrated significantly higher tensile and shear bond strength compared with other groups.</p> </sec> <sec> <title id="sect0025">Conclusion</title> <p id="spar0020">Although LED and PAC showed approximately peak irradiance five times higher than TQH, there is no significant difference in tensile and shear bond strength between TQH and PAC. It appears that LCGIC would have provided greater bond strength under various conditions of LED-10's.</p> </sec> </abstract> … (more)
- Is Part Of:
- Orthodontic waves. Volume 74:Issue 3(2015:Sep.)
- Journal:
- Orthodontic waves
- Issue:
- Volume 74:Issue 3(2015:Sep.)
- Issue Display:
- Volume 74, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 74
- Issue:
- 3
- Issue Sort Value:
- 2015-0074-0003-0000
- Page Start:
- 76
- Page End:
- 82
- Publication Date:
- 2015-09
- Subjects:
- Orthodontics -- Periodicals
Orthodontics -- Periodicals
Orthodontie -- Périodiques
Orthodontie
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
617.643 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=115074 ↗
http://www.sciencedirect.com/science/journal/13440241 ↗
https://www.tandfonline.com/toc/todw20/current ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.odw.2015.03.001 ↗
- Languages:
- English
- ISSNs:
- 1344-0241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6296.109500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3633.xml