D‐dimers Are a Predictor of Clot Volume Inside Membrane Oxygenators During Extracorporeal Membrane Oxygenation. Issue 9 (7th April 2015)
- Record Type:
- Journal Article
- Title:
- D‐dimers Are a Predictor of Clot Volume Inside Membrane Oxygenators During Extracorporeal Membrane Oxygenation. Issue 9 (7th April 2015)
- Main Title:
- D‐dimers Are a Predictor of Clot Volume Inside Membrane Oxygenators During Extracorporeal Membrane Oxygenation
- Authors:
- Dornia, Christian
Philipp, Alois
Bauer, Stefan
Stroszczynski, Christian
Schreyer, Andreas G.
Müller, Thomas
Koehl, Gudrun E.
Lehle, Karla - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Thrombosis inside the membrane oxygenator (MO) is a critical complication during venovenous extracorporeal membrane oxygenation (ECMO). The aim of this study was to prove if thrombotic clots manifest within the MO when D‐dimer levels are elevated over a long‐term period. Heparin‐coated polymethylpentene MOs (<italic>n</italic> = 13) were exchanged due to high plasma D‐dimer levels. Clot volume was calculated using multidetector computed tomography (MDCT). Coagulation parameters and MO function were analyzed before and after MO exchange. Before MO exchange, D‐dimer levels increased significantly in each patient (11.5 [6.5–15.5] mg/L to 35.0 [34–35] mg/L, <italic>P</italic> ≤ 0.001). High levels of D‐dimers were tolerated for 1 to 6 days. Additionally, fibrinogen concentration (<italic>n</italic> = 8) and platelet count decreased (<italic>n</italic> = 8). Within 48 h after exchange, D‐dimer levels decreased significantly (<italic>n</italic> = 11, 12 [8–16] mg/L, <italic>P</italic> = 0.004). Fibrinogen concentration and platelet counts increased. Clots were found in all MOs in the inlet part of the device. Clot volume (16–106 cm<sup>3</sup>) did not correlate with MO support time but increased significantly when high D‐dimer levels were accepted for &gt;2 days. An increase or high levels of D‐dimers in absence of other explaining pathology during ECMO therapy reflected coagulation activity within the MO. Evidence of<abstract abstract-type="main"> <title>Abstract</title> <p>Thrombosis inside the membrane oxygenator (MO) is a critical complication during venovenous extracorporeal membrane oxygenation (ECMO). The aim of this study was to prove if thrombotic clots manifest within the MO when D‐dimer levels are elevated over a long‐term period. Heparin‐coated polymethylpentene MOs (<italic>n</italic> = 13) were exchanged due to high plasma D‐dimer levels. Clot volume was calculated using multidetector computed tomography (MDCT). Coagulation parameters and MO function were analyzed before and after MO exchange. Before MO exchange, D‐dimer levels increased significantly in each patient (11.5 [6.5–15.5] mg/L to 35.0 [34–35] mg/L, <italic>P</italic> ≤ 0.001). High levels of D‐dimers were tolerated for 1 to 6 days. Additionally, fibrinogen concentration (<italic>n</italic> = 8) and platelet count decreased (<italic>n</italic> = 8). Within 48 h after exchange, D‐dimer levels decreased significantly (<italic>n</italic> = 11, 12 [8–16] mg/L, <italic>P</italic> = 0.004). Fibrinogen concentration and platelet counts increased. Clots were found in all MOs in the inlet part of the device. Clot volume (16–106 cm<sup>3</sup>) did not correlate with MO support time but increased significantly when high D‐dimer levels were accepted for &gt;2 days. An increase or high levels of D‐dimers in absence of other explaining pathology during ECMO therapy reflected coagulation activity within the MO. Evidence of clots within the MO at high D‐dimer levels and decrease after exchange underline the relevance of D‐dimer testing during ECMO treatment. Besides, surveillance of MOs during ongoing ECMO therapy will help to predict clot formation, and to avoid system‐induced coagulation disorders as well as critical situations.</p> </abstract> … (more)
- Is Part Of:
- Artificial organs. Volume 39:Issue 9(2015:Sep.)
- Journal:
- Artificial organs
- Issue:
- Volume 39:Issue 9(2015:Sep.)
- Issue Display:
- Volume 39, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 39
- Issue:
- 9
- Issue Sort Value:
- 2015-0039-0009-0000
- Page Start:
- 782
- Page End:
- 787
- Publication Date:
- 2015-04-07
- Subjects:
- Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.12460 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3761.xml