Preparation of a porous conductive scaffold from aniline pentamer‐modified polyurethane/PCL blend for cardiac tissue engineering. Issue 10 (30th March 2015)
- Record Type:
- Journal Article
- Title:
- Preparation of a porous conductive scaffold from aniline pentamer‐modified polyurethane/PCL blend for cardiac tissue engineering. Issue 10 (30th March 2015)
- Main Title:
- Preparation of a porous conductive scaffold from aniline pentamer‐modified polyurethane/PCL blend for cardiac tissue engineering
- Authors:
- Baheiraei, Nafiseh
Yeganeh, Hamid
Ai, Jafar
Gharibi, Reza
Ebrahimi‐Barough, Somayeh
Azami, Mahmoud
Vahdat, Sadaf
Baharvand, Hossein - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>A novel biodegradable electroactive polyurethane containing aniline pentamer (AP) was blended with polycaprolactone (PCL). The prepared blend (PB) and PCL were further fabricated in to scaffolds using a mixture of poly(ethylene glycol) and salt particles in a double porogen particulate leaching and compression molding methodology. Scaffolds held open and interconnected pores having pore size ranging from several μm to 150 µm. PB scaffolds had compression modulus and strength of 4.1 and 1.3 MPa, respectively. The conductivity of the scaffold was measured as 10<sup>−5</sup> ± 0.09 S .cm<sup>−1</sup> and preserved for at least 100 h post fabrication. Scaffolds supported neonatal cardiomyocytes adhesion and growth with PB showing more extensive effect on the expression of the cardiac genes involved in muscle contraction and relaxation (troponin‐T) and cytoskeleton alignment (actinin‐4). Our results highlight the potential of incorporation of AP as an electroactive moiety for induction of cardiomyocyte proliferation and repair of damaged heart tissue. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 103A: 3179–3187, 2015.</p> </abstract>
- Is Part Of:
- Journal of biomedical materials research. Volume 103:Issue 10(2015:Oct.)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 103:Issue 10(2015:Oct.)
- Issue Display:
- Volume 103, Issue 10 (2015)
- Year:
- 2015
- Volume:
- 103
- Issue:
- 10
- Issue Sort Value:
- 2015-0103-0010-0000
- Page Start:
- 3179
- Page End:
- 3187
- Publication Date:
- 2015-03-30
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4965 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jbm.a.35447 ↗
- Languages:
- English
- ISSNs:
- 1549-3296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.720000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3817.xml