Viewing rate and reproducibility of papillary muscle areas in foetal atrioventricular valves using spatio-temporal image correlation in the rendering mode in congenital heart disease. (August 2015)
- Record Type:
- Journal Article
- Title:
- Viewing rate and reproducibility of papillary muscle areas in foetal atrioventricular valves using spatio-temporal image correlation in the rendering mode in congenital heart disease. (August 2015)
- Main Title:
- Viewing rate and reproducibility of papillary muscle areas in foetal atrioventricular valves using spatio-temporal image correlation in the rendering mode in congenital heart disease
- Authors:
- Rolo, Liliam Cristine
Pietrolucci, Maria Elena
Araujo Júnior, Edward
Barros, Fernanda Silveira Bello
Nardozza, Luciano Marcondes Machado
Martins, Wellington P.
Moron, Antonio Fernandes
Arduin, Domenico
Rizzo, Giuseppe - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Objective</italic>: To assess the viewing rate and reproducibility of areas of the papillary muscles (PMs) of foetal atrioventricular valves using spatio-temporal image correlation (STIC) in the rendering mode in congenital heart disease (CHD).</p> <p> <italic>Methods</italic>: We retrospectively reviewed 40 4D-STIC volume datasets from different foetal CHD cases at a gestational age of 18w6d–35w6d. The following papillary muscles (PMs) were assessed: antero-lateral (MPAL) and postero-medial (MPPM) to the mitral valve and antero-superior (MPAS), inferior (MPI) and septal (MPS) to the tricuspid valve. To assess the valve viewing rate, percentages (%) were used. The concordance correlation coefficient (CCC) was used to assess inter-observer reliability.</p> <p> <italic>Results</italic>: Two independent observers concluded that a complete examination of the PMs was impossible in 11 cases, yielding a viewing rate of 72.5%. The complete examination of the PMs of the tricuspid and mitral valves was possible by both examiners in 33/40 (82.5%) and 32/40 (80.0%) cases, respectively. We observed moderate to good inter-observer reliability with CCCs of 0.95, 0.92, 0.97, 0.96 and 0.97 for MPS, MPI, MPAS, MPAL and MPPM, respectively.</p> <p> <italic>Conclusion</italic>: The viewing rate of PM areas in different CHDs using STIC in the rendering mode was moderate. The inter-observer reproducibility was moderate to good for all PM areas.</p><abstract> <title>Abstract</title> <p> <italic>Objective</italic>: To assess the viewing rate and reproducibility of areas of the papillary muscles (PMs) of foetal atrioventricular valves using spatio-temporal image correlation (STIC) in the rendering mode in congenital heart disease (CHD).</p> <p> <italic>Methods</italic>: We retrospectively reviewed 40 4D-STIC volume datasets from different foetal CHD cases at a gestational age of 18w6d–35w6d. The following papillary muscles (PMs) were assessed: antero-lateral (MPAL) and postero-medial (MPPM) to the mitral valve and antero-superior (MPAS), inferior (MPI) and septal (MPS) to the tricuspid valve. To assess the valve viewing rate, percentages (%) were used. The concordance correlation coefficient (CCC) was used to assess inter-observer reliability.</p> <p> <italic>Results</italic>: Two independent observers concluded that a complete examination of the PMs was impossible in 11 cases, yielding a viewing rate of 72.5%. The complete examination of the PMs of the tricuspid and mitral valves was possible by both examiners in 33/40 (82.5%) and 32/40 (80.0%) cases, respectively. We observed moderate to good inter-observer reliability with CCCs of 0.95, 0.92, 0.97, 0.96 and 0.97 for MPS, MPI, MPAS, MPAL and MPPM, respectively.</p> <p> <italic>Conclusion</italic>: The viewing rate of PM areas in different CHDs using STIC in the rendering mode was moderate. The inter-observer reproducibility was moderate to good for all PM areas.</p> </abstract> … (more)
- Is Part Of:
- Journal of maternal-fetal & neonatal medicine. Volume 28:Number 12(2015)
- Journal:
- Journal of maternal-fetal & neonatal medicine
- Issue:
- Volume 28:Number 12(2015)
- Issue Display:
- Volume 28, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 28
- Issue:
- 12
- Issue Sort Value:
- 2015-0028-0012-0000
- Page Start:
- 1375
- Page End:
- 1380
- Publication Date:
- 2015-08
- Subjects:
- Obstetrics -- Periodicals
Perinatology -- Periodicals
Infants (Newborn) -- Diseases -- Periodicals
Neonatology -- Periodicals
618.2 - Journal URLs:
- http://informahealthcare.com/loi/jmf ↗
http://informahealthcare.com ↗ - DOI:
- ↗
- Languages:
- English
- ISSNs:
- 1476-7058
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.332000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3999.xml