Hybrid Technique for Cervical Pedicle Screw Placement. Issue 15 (1st August 2015)
- Record Type:
- Journal Article
- Title:
- Hybrid Technique for Cervical Pedicle Screw Placement. Issue 15 (1st August 2015)
- Main Title:
- Hybrid Technique for Cervical Pedicle Screw Placement
- Authors:
- Kim, Moon-Kyu
Cho, Sung-Min
You, Seung-Hoon
Kim, In-Beom
Kwak, Dai-Soon - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Study Design.</title> <p>Cadaver study and clinical application; a pilot study.</p> </sec> <sec> <title>Objective.</title> <p>To minimize muscle dissection and enhance accuracy of cervical pedicle screw (CPS) placement by using a percutaneous cannula system.</p> </sec> <sec> <title>Summary of Background Data.</title> <p>Many studies have reported that the most frequent misplacement of CPSs is breach of the lateral wall; thus, an easy technique for securing medial convergence is required. We developed a percutaneous cannula system for this purpose and report the results of a cadaver study and its clinical application.</p> </sec> <sec> <title>Methods.</title> <p>A cadaver study was conducted to confirm the possibility of this percutaneous technique in 5 specimens (50 CPSs, C3–C7). Then, the technique was applied in 8 patients (40 CPSs, C3–C7). The surgical technique was a hybrid of miniopen surgery and the use of percutaneous cannula system under lateral fluoroscopic guidance. Entry holes were made in the open field and a cannula was used for tapping and insertion of CPSs. A stiff pedicle probe through the cannula was used to locate the pedicle in the lateral mass.</p> </sec> <sec> <title>Results.</title> <p>In the cadaver study, there were 12 (24%) misplacements among 50 CPSs used. The hybrid technique was applied clinically in 4 traumatic, 2 degenerative, and 2 failed back surgery lesions. Thirty<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Study Design.</title> <p>Cadaver study and clinical application; a pilot study.</p> </sec> <sec> <title>Objective.</title> <p>To minimize muscle dissection and enhance accuracy of cervical pedicle screw (CPS) placement by using a percutaneous cannula system.</p> </sec> <sec> <title>Summary of Background Data.</title> <p>Many studies have reported that the most frequent misplacement of CPSs is breach of the lateral wall; thus, an easy technique for securing medial convergence is required. We developed a percutaneous cannula system for this purpose and report the results of a cadaver study and its clinical application.</p> </sec> <sec> <title>Methods.</title> <p>A cadaver study was conducted to confirm the possibility of this percutaneous technique in 5 specimens (50 CPSs, C3–C7). Then, the technique was applied in 8 patients (40 CPSs, C3–C7). The surgical technique was a hybrid of miniopen surgery and the use of percutaneous cannula system under lateral fluoroscopic guidance. Entry holes were made in the open field and a cannula was used for tapping and insertion of CPSs. A stiff pedicle probe through the cannula was used to locate the pedicle in the lateral mass.</p> </sec> <sec> <title>Results.</title> <p>In the cadaver study, there were 12 (24%) misplacements among 50 CPSs used. The hybrid technique was applied clinically in 4 traumatic, 2 degenerative, and 2 failed back surgery lesions. Thirty CPSs were inserted using the percutaneous cannula system and 10 were inserted using a cannula as a retractor. Misplacement occurred in 6.7% (n = 2) and 20% (n = 2) pedicles, respectively, and there were no symptomatic complications (total incidence, 10%). An additional incision for the cannula system can be made for 2-level CPS insertions.</p> </sec> <sec> <title>Conclusion.</title> <p>Use of the percutaneous cannula system facilitated a secure convergence angle for CPS insertion without extending muscle dissection or shifting cervical alignment because of muscle retraction. Moreover, this system can be used for CPS insertion in bull-necked patients.</p> <p> <bold>Level of Evidence:</bold> 3</p> </sec> </abstract> … (more)
- Is Part Of:
- Spine. Volume 40:Issue 15(2015)
- Journal:
- Spine
- Issue:
- Volume 40:Issue 15(2015)
- Issue Display:
- Volume 40, Issue 15 (2015)
- Year:
- 2015
- Volume:
- 40
- Issue:
- 15
- Issue Sort Value:
- 2015-0040-0015-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-08-01
- Subjects:
- Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000000986 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3605.xml