Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm. Issue 4 (July 2015)
- Record Type:
- Journal Article
- Title:
- Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm. Issue 4 (July 2015)
- Main Title:
- Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm
- Authors:
- Onishi, Hiromitsu
Kockelkoren, Remko
Kim, Tonsok
Hori, Masatoshi
Nakamoto, Atsushi
Tsuboyama, Takahiro
Sakane, Makoto
Tatsumi, Mitsuaki
Uranishi, Ayumi
Tanaka, Toshiya
BSc, Akira Taniguchi
Enchi, Yukihiro
Satoh, Kazuhiko
Tomiyama, Noriyuki - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective</title> <p>To evaluate the image quality and radiation dose reduction in pelvic computed tomography (CT) achieved with an adaptive iterative dose reduction 3-dimensional (AIDR 3D) algorithm using a phantom model.</p> </sec> <sec> <title>Methods</title> <p>Two phantoms were scanned using a 320-detector row CT scanner with 8 tube current levels, and the images were reconstructed with a standard filtered back projection (FBP) algorithm and with an AIDR 3D algorithm.</p> </sec> <sec> <title>Results</title> <p>Compared with FBP, AIDR 3D reduced image noise and improved contrast-to-noise ratios. The diagnostic performance for detection of low-contrast targets of AIDR 3D images obtained with 100 mA at 120 kVp was almost as good as that of the FBP images obtained with 200 mA.</p> </sec> <sec> <title>Conclusions</title> <p>The AIDR 3D algorithm substantially reduced image noise and improved the image quality of pelvic CT images compared with those obtained with the FBP algorithm and can thus be considered a promising technique for low-dose pelvic CT examinations.</p> </sec> </abstract>
- Is Part Of:
- Journal of computer assisted tomography. Volume 39:Issue 4(2015)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 39:Issue 4(2015)
- Issue Display:
- Volume 39, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 39
- Issue:
- 4
- Issue Sort Value:
- 2015-0039-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000242 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3266.xml