Ultralow-Dose Abdominal Computed Tomography. Issue 4 (July 2015)
- Record Type:
- Journal Article
- Title:
- Ultralow-Dose Abdominal Computed Tomography. Issue 4 (July 2015)
- Main Title:
- Ultralow-Dose Abdominal Computed Tomography
- Authors:
- Khawaja, Ranish Deedar Ali
Singh, Sarabjeet
Blake, Michael
Harisinghani, Mukesh
Choy, Gary
Karosmanoglu, Ali
Padole, Atul
Pourjabbar, Saravenaz
Do, Synho
Kalra, Mannudeep K. - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Purpose</title> <p>To assess lesion detection and image quality of ultralow-dose (ULD) abdominal computed tomography (CT) reconstructed with filtered back projection (FBP) and 2 iterative reconstruction techniques: <italic>hybrid-based</italic> iDose, and <italic>image-based</italic> SafeCT.</p> </sec> <sec> <title>Materials and Methods</title> <p>In this institutional review board–approved ongoing prospective clinical study, 41 adult patients provided written informed consent for an additional ULD abdominal CT examination immediately after standard dose (SD) CT exam on a 256-slice multidetector computed tomography (iCT, Philips-Healthcare). The SD examination (size-specific dose estimate, 10 ± 3 mGy) was performed at 120 kV with automatic exposure control, and reconstructed with FBP. The ULD examination (1.5 ± 0.4 mGy) was performed at 120 kV and fixed tube current of 17 to 20 mAs/slice to achieve ULD radiation dose, with the rest of the scan parameters same as SD examination. The ULD data were reconstructed with (a) FBP, (b) iDose, and (c) SafeCT. Lesions were detected on ULD FBP series and compared to SD FBP "reference-standard" series. True lesions, pseudolesions, and missed lesions were recorded. Four abdominal radiologists independently blindly performed subjective image quality. Objective image quality included image noise calculation and noise spectral density plots.</p> </sec> <sec><abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Purpose</title> <p>To assess lesion detection and image quality of ultralow-dose (ULD) abdominal computed tomography (CT) reconstructed with filtered back projection (FBP) and 2 iterative reconstruction techniques: <italic>hybrid-based</italic> iDose, and <italic>image-based</italic> SafeCT.</p> </sec> <sec> <title>Materials and Methods</title> <p>In this institutional review board–approved ongoing prospective clinical study, 41 adult patients provided written informed consent for an additional ULD abdominal CT examination immediately after standard dose (SD) CT exam on a 256-slice multidetector computed tomography (iCT, Philips-Healthcare). The SD examination (size-specific dose estimate, 10 ± 3 mGy) was performed at 120 kV with automatic exposure control, and reconstructed with FBP. The ULD examination (1.5 ± 0.4 mGy) was performed at 120 kV and fixed tube current of 17 to 20 mAs/slice to achieve ULD radiation dose, with the rest of the scan parameters same as SD examination. The ULD data were reconstructed with (a) FBP, (b) iDose, and (c) SafeCT. Lesions were detected on ULD FBP series and compared to SD FBP "reference-standard" series. True lesions, pseudolesions, and missed lesions were recorded. Four abdominal radiologists independently blindly performed subjective image quality. Objective image quality included image noise calculation and noise spectral density plots.</p> </sec> <sec> <title>Results</title> <p>All true lesions (n, 52: liver metastases, renal cysts, diverticulosis) in SD FBP images were detected in ULD images. Although there were no missed or pseudolesions on ULD iDose and ULD SafeCT images, appearance of small low-contrast hepatic lesions was suboptimal. The ULD FBP images were unacceptable across all patients for both lesion detection and image quality. In patients with a body mass index (BMI) of 25 kg/m<sup>2</sup> or less, ULD iDose and ULD SafeCT images were acceptable for image quality that was close to SD FBP for both normal and abnormal abdominal and pelvic structures. With increasing BMI, the image quality of ULD images was deemed unacceptable due to photo starvation. Evaluation of kidney stones with ULD iDose/SafeCT images was found acceptable regardless of patient size. Image noise levels were significantly lower in ULD iDose and ULD SafeCT images compared to ULD FBP (<italic>P</italic> &lt; 0.01).</p> </sec> <sec> <title>Conclusions</title> <p>Preliminary results show that ULD abdominal CT reconstructed with iterative reconstruction techniques is achievable in smaller patients (BMI ⩽ 25 kg/m<sup>2</sup>) but remains a challenge for overweight to obese patients. Lesion detection is similar in full-dose SD FBP and ULD iDose/SafeCT images, with suboptimal visibility of low-contrast lesions in ULD images.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 39:Issue 4(2015)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 39:Issue 4(2015)
- Issue Display:
- Volume 39, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 39
- Issue:
- 4
- Issue Sort Value:
- 2015-0039-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000248 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3265.xml